    "id": "apple",
    "title": "Apple Watch Heart Rate Accuracy Study",
    "citation": "Apple",
    "year": 2026,
    "doi": null,
    "pmid": null,
    "url": "https://www.apple.com/health/pdf/Heart_Rate_Accuracy_Study_2026.pdf",
    "setting": "Exercise",
    "devices": "Apple Watch Series 12 and six comparator devices",
    "reference": "Polar H10 ECG chest strap",
    "people": 1254,
    "finding": "Apple reported a lower error for Series 12 in 139 of 159 activity-by-measure comparisons at its 99% confidence criterion. The paper used Apple’s internal logger for Series 12 and device-specific export streams for rivals.",
    "locator": "Figures 1–3",
    "evidence": "Manufacturer white paper",
    "resultsStudy": null
  },
  {
    "id": "pmid-41516757",
    "title": "Impact of Helicopter Vibrations on In-Ear PPG Monitoring for Vital Signs-Mountain Rescue Technology Study (MoReTech)",
    "citation": "Benkert A et al.",
    "year": 2026,
    "doi": "10.3390/s26010324",
    "pmid": "41516757",
    "url": "https://pubmed.ncbi.nlm.nih.gov/41516757/",
    "setting": "Sleep and rest",
    "devices": "In-ear optical prototype",
    "reference": "Clinical ECG",
    "people": 17,
    "finding": "Pulse-rate concordance with ECG was 0.96 both at rest and under helicopter-simulator vibration.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-42280898",
    "title": "A Speed-Dependent Assessment of E-Textile-Based Sensor Technology: Validity of the Prevayl Wearable Heart Rate Monitor",
    "citation": "Burgess LC et al.",
    "year": 2026,
    "doi": "10.3390/s26113378",
    "pmid": "42280898",
    "url": "https://pubmed.ncbi.nlm.nih.gov/42280898/",
    "setting": "Exercise",
    "devices": "Prevayl smart textile monitor",
    "reference": "3-lead ECG",
    "people": 26,
    "finding": "In a 16-minute incremental treadmill test, median beat count from the textile sensor was 100.5% of the reference. The study also compared heart rate at different speeds.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-42944412",
    "title": "Pulse vs. R-R Interval: Validity and Reliability of the Garmin Elevate v4 Sensor for Ultra-Short HR and HRV Monitoring in Healthy Adults.",
    "citation": "Casanova-Lizón A et al.",
    "year": 2026,
    "doi": "10.3390/s26206549",
    "pmid": "42944412",
    "url": "https://pubmed.ncbi.nlm.nih.gov/42944412/",
    "setting": "Sleep and rest",
    "devices": "Garmin Forerunner 955",
    "reference": "BIOPAC ECG",
    "people": 23,
    "finding": "During short seated and supine tests, resting heart rate correlated at 0.94 or higher against ECG.",
    "locator": "Section 3.4 and Figure 6",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-41682372",
    "title": "Validity of the Polar H10 for Continuous Measures of Heart Rate and Heart Rate Synchrony Analysis.",
    "citation": "Chung V et al.",
    "year": 2026,
    "doi": "10.3390/s26030855",
    "pmid": "41682372",
    "url": "https://pubmed.ncbi.nlm.nih.gov/41682372/",
    "setting": "Sleep and rest",
    "devices": "Polar H10",
    "reference": "Laboratory ECG",
    "people": null,
    "finding": "Polar H10 heart rate correlated above 0.99 with ECG during seated audiovisual tasks.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-42060626",
    "title": "Accuracy of heart rate measurement using AirPods Pro 3 during graded treadmill exercise: A laboratory-based validation study.",
    "citation": "Doherty C et al.",
    "year": 2026,
    "doi": "10.1371/journal.pdig.0001373",
    "pmid": "42060626",
    "url": "https://pubmed.ncbi.nlm.nih.gov/42060626/",
    "setting": "Exercise",
    "devices": "AirPods Pro 3",
    "reference": "Polar H10",
    "people": 40,
    "finding": "Mean absolute error was 2.08 bpm in five-second treadmill windows. The agreement limits were roughly −10 to +10 bpm, with more spread at higher rates.",
    "locator": "Abstract and Table 2",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-41701929",
    "title": "Accuracy of Optical Heart Rate Measurements for 10 Commercial Wearables in Different Climate Conditions and Activities: Instrument Validation Study.",
    "citation": "Gielen J et al.",
    "year": 2026,
    "doi": "10.2196/85186",
    "pmid": "41701929",
    "url": "https://formative.jmir.org/2026/1/e85186",
    "setting": "Exercise",
    "devices": "Fitbit Charge 6, Fitbit Inspire 3, Garmin Vivosmart 5, Garmin Vivoactive 5, Apple Watch SE, Google Pixel Watch 2, Polar Ignite 3, Polar Pacer, Xiaomi Watch 2, Oura Ring Gen 3",
    "reference": "Zephyr BioHarness ECG",
    "people": 45,
    "finding": "Across the climate chamber protocol, median participant mean absolute error was 4.5 bpm for Fitbit Charge 6 and 4.9 bpm for Pixel Watch 2.",
    "locator": "Tables 1–3",
    "evidence": "Published research",
    "resultsStudy": "walking"
  },
  {
    "id": "pmid-41990212",
    "title": "Heart Rate Estimation Using the Galaxy Watch During Maximal Cardiopulmonary Exercise Testing: Cross-Sectional Validation Study.",
    "citation": "Inoue A et al.",
    "year": 2026,
    "doi": "10.2196/81917",
    "pmid": "41990212",
    "url": "https://pubmed.ncbi.nlm.nih.gov/41990212/",
    "setting": "Exercise",
    "devices": "Samsung Galaxy Watch 6",
    "reference": "Polar H10",
    "people": 55,
    "finding": "During maximal treadmill testing, the mean bias was −2.67 bpm, with limits of agreement from −16.90 to +11.57 bpm.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-42438855",
    "title": "Comparison of heart rate measurement accuracy among commercially available photoplethysmography-based wearable devices across exercise intensities.",
    "citation": "Jeong Y et al.",
    "year": 2026,
    "doi": "10.20463/pan.2026.0032",
    "pmid": "42438855",
    "url": "https://pubmed.ncbi.nlm.nih.gov/42438855/",
    "setting": "Exercise",
    "devices": "Polar Verity Sense, Polar Pacer Pro, Apple Watch SE, Galaxy Watch 6",
    "reference": "Polar H10",
    "people": 37,
    "finding": "Errors generally fell with intensity during this treadmill protocol. Apple Watch SE and Polar Verity Sense had lower mean absolute errors overall than the two other devices.",
    "locator": "Table 3 and Figure 4",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-42229511",
    "title": "Validation of a novel multi-sensor wearable for measuring heart rate, steps, and energy expenditure in laboratory and simulated free-living protocols",
    "citation": "Kim T et al.",
    "year": 2026,
    "doi": "10.1088/1361-6579/ae76b8",
    "pmid": "42229511",
    "url": "https://pubmed.ncbi.nlm.nih.gov/42229511/",
    "setting": "Exercise",
    "devices": "DOFIT PRO",
    "reference": "ECG chest strap",
    "people": null,
    "finding": "Absolute percentage error ranged from 0.61% to 5.18% at rest and in recovery, and from 32.96% to 41.77% while jogging, depending on wrist placement.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-41493142",
    "title": "Smart swim goggles accurately measure heart rate during swim training: A criterion validation study.",
    "citation": "Kits A et al.",
    "year": 2026,
    "doi": "10.1080/02640414.2025.2610787",
    "pmid": "41493142",
    "url": "https://pubmed.ncbi.nlm.nih.gov/41493142/",
    "setting": "Exercise",
    "devices": "Optical swim goggles",
    "reference": "Garmin HRM-Swim",
    "people": 25,
    "finding": "Mean workout heart-rate error averaged 1.0% in the swim comparison. Concordance was 0.99 for workout averages and 0.91 for intervals.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-42197732",
    "title": "PPG-Based Heart Rate Accuracy in Hispanic Adults with Fitzpatrick III-V Skin Tones: An Evaluation of Body Composition and Skin-Tone Effects.",
    "citation": "Kostrna J et al.",
    "year": 2026,
    "doi": "10.3390/s26102922",
    "pmid": "42197732",
    "url": "https://pmc.ncbi.nlm.nih.gov/articles/PMC13210717/",
    "setting": "Exercise",
    "devices": "Apple Watch Series 8, Garmin Forerunner 955, Fitbit Sense 2, Samsung Galaxy Watch 5",
    "reference": "Polar H10",
    "people": 58,
    "finding": "During cycling, absolute error averaged 2.51 bpm for Apple and 2.93 bpm for Garmin. The paper reports different usable sample sizes by model.",
    "locator": "Table 1",
    "evidence": "Published research",
    "resultsStudy": "cycling"
  },
  {
    "id": "pmid-42743109",
    "title": "The accuracy of VO2 max, heart rate and energy expenditure measurements from Google Pixel Watch 3.",
    "citation": "Lambe R et al.",
    "year": 2026,
    "doi": "10.1371/journal.pone.0356808",
    "pmid": "42743109",
    "url": "https://pubmed.ncbi.nlm.nih.gov/42743109/",
    "setting": "Exercise",
    "devices": "Google Pixel Watch 3",
    "reference": "Polar H10",
    "people": 34,
    "finding": "In 33 of 34 recruited participants with paired heart-rate data, treadmill mean absolute error was 4.06 bpm (2.73%), with bias of −2.39 bpm and agreement limits of −24.42 to +19.65 bpm.",
    "locator": "Results, Table 2 and Figure 2",
    "evidence": "Google-funded study",
    "resultsStudy": null
  },
  {
    "id": "repeat-lifting",
    "title": "Assessing Heart-Rate Display Reliability and Agreement Error Between Four Smartwatches and an Electrocardiography Criterion After Resistance Exercise",
    "citation": "Lee, Bae and Ko",
    "year": 2026,
    "doi": "10.3390/bioengineering13111269",
    "pmid": null,
    "url": "https://www.mdpi.com/2306-5354/13/11/1269",
    "setting": "Exercise",
    "devices": "Apple Watch Series 7, Galaxy Watch 4, Fitbit Charge 5, Garmin Vivosmart 5",
    "reference": "ECG display",
    "people": 60,
    "finding": "At five seconds after a set, absolute error averaged 8.71 bpm on Apple Watch and 25.43 bpm on Galaxy Watch. The study used a separate cohort from the earlier 70-person lifting trial.",
    "locator": "Tables 2, 3 and 5",
    "evidence": "Published research",
    "resultsStudy": "repeat-lifting"
  },
  {
    "id": "pmid-42318291",
    "title": "Impact of central adiposity on the heart rate and calorie estimation accuracy of diverse smartwatches and the resulting subjective exercise experience",
    "citation": "Lertyongphati A et al.",
    "year": 2026,
    "doi": "10.3389/fspor.2026.1829700",
    "pmid": "42318291",
    "url": "https://doi.org/10.3389/fspor.2026.1829700",
    "setting": "Exercise",
    "devices": "Apple Watch SE, Garmin Forerunner, Xiaomi Mi Watch Lite, ThaiSook Watch",
    "reference": "Polar H10",
    "people": 40,
    "finding": "During the full exercise session, Apple and Garmin had correlations of at least 0.98 with the strap. The paper gives conflicting Garmin model numbers.",
    "locator": "Table 2 and Figure 7",
    "evidence": "Study funder developed ThaiSook Watch",
    "resultsStudy": null
  },
  {
    "id": "pmid-42325812",
    "title": "Validation of the ECTemp™ algorithm in construction workers: a comparison of photoplethysmography smartwatch and chest strap heart rate monitors.",
    "citation": "Lignier MJ et al.",
    "year": 2026,
    "doi": "10.1088/2515-7620/ae7bc5",
    "pmid": "42325812",
    "url": "https://pubmed.ncbi.nlm.nih.gov/42325812/",
    "setting": "Daily life",
    "devices": "Garmin Instinct 2",
    "reference": "Polar H10",
    "people": 60,
    "finding": "Over a construction work shift, Garmin's mean difference from the strap was 1.6 bpm, with a reported spread of 4.9 bpm.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-40968160",
    "title": "Influence of skin pigmentation on the accuracy and data quality of photoplethysmographic heart rate measurement during exercise.",
    "citation": "Mulholland AM et al.",
    "year": 2026,
    "doi": "10.1007/s00421-025-05977-x",
    "pmid": "40968160",
    "url": "https://pubmed.ncbi.nlm.nih.gov/40968160/",
    "setting": "Exercise",
    "devices": "Apple Watch Series 8, Garmin Vivosmart 5, SlateSafety Band V2",
    "reference": "Polar H10",
    "people": 28,
    "finding": "Across rest, cycling and recovery, pigmentation was associated with about 1 bpm more error on the SlateSafety band. Missing data were more frequent with darker pigmentation across all three tested devices.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-42702963",
    "title": "Validation of heart rate measurements from the polar verity sense during the submaximal Ekblom-Bak test in adult individuals with obesity.",
    "citation": "Onstad GR et al.",
    "year": 2026,
    "doi": "10.2340/jrm.v58.44975",
    "pmid": "42702963",
    "url": "https://pubmed.ncbi.nlm.nih.gov/42702963/",
    "setting": "Exercise",
    "devices": "Polar Verity Sense",
    "reference": "Polar H10",
    "people": 48,
    "finding": "The two arm placements had intraclass and concordance coefficients between 0.998 and 0.999 during submaximal cycling in adults with obesity.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-41799782",
    "title": "A Pilot Study Examining the Convergent Validity of Two Commercially Available Heart Rate Monitoring Devices During Swimming of Different Intensities and Strokes",
    "citation": "Reynolds H et al.",
    "year": 2026,
    "doi": "10.70252/ijes2026701",
    "pmid": "41799782",
    "url": "https://pubmed.ncbi.nlm.nih.gov/41799782/",
    "setting": "Exercise",
    "devices": "Optical swim heart-rate monitor",
    "reference": "ECG chest monitor",
    "people": 19,
    "finding": "Across the swim tests, the optical device averaged 150.7 bpm versus 155.9 bpm for the chest monitor. It returned more readings than the chest monitor.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-42669164",
    "title": "Assessing the agreement and reliability of Magene ® for heart rate monitoring",
    "citation": "Rodrigues MAM et al.",
    "year": 2026,
    "doi": "10.1177/09544119261477973",
    "pmid": "42669164",
    "url": "https://pubmed.ncbi.nlm.nih.gov/42669164/",
    "setting": "Exercise",
    "devices": "Magene chest strap",
    "reference": "Polar H7",
    "people": 68,
    "finding": "The Magene averaged 1.42 bpm below the Polar at rest, 0.66 bpm below during exercise and 0.10 bpm below at maximum effort.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-42099266",
    "title": "Reliability and validity of a smartwatch with a photoplethysmograph: Comparison with a Holter electrocardiograph.",
    "citation": "Tan C et al.",
    "year": 2026,
    "doi": "10.1080/07420528.2026.2669593",
    "pmid": "42099266",
    "url": "https://pubmed.ncbi.nlm.nih.gov/42099266/",
    "setting": "Daily life",
    "devices": "Garmin Vivosmart 5",
    "reference": "Holter ECG",
    "people": 10,
    "finding": "Across 72 to 96 hours of free-living use, mean bias was 1.16 bpm. The mean limits spanned roughly 12.4 bpm either side of bias.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "temple",
    "title": "Temple Heart Rate Accuracy Study",
    "citation": "Temple Research",
    "year": 2026,
    "doi": null,
    "pmid": null,
    "url": "https://cdn.temple.com/research/temple-heart-rate-accuracy-study.pdf",
    "setting": "Exercise",
    "devices": "Temple, Apple Watch Series 12, Fitbit Air, WHOOP MG, Garmin Forerunner 970, Oura Ring 5",
    "reference": "Taped Polar H10 ECG chest strap",
    "people": 43,
    "finding": "With defined failure episodes removed, the manufacturer reported mean absolute errors of 1.18 bpm for Temple, 1.94 bpm for Apple Watch and 5.21 bpm for Oura Ring 5.",
    "locator": "Tables 2–3 and Figure 3, pages 4, 9–10",
    "evidence": "Manufacturer white paper",
    "resultsStudy": "temple"
  },
  {
    "id": "pmid-42350250",
    "title": "Smartwatch-Based Heart Rate Detection in Atrial, Ventricular and Pulseless Arrhythmias.",
    "citation": "Turnbull S et al.",
    "year": 2026,
    "doi": "10.1016/j.hlc.2026.02.016",
    "pmid": "42350250",
    "url": "https://pubmed.ncbi.nlm.nih.gov/42350250/",
    "setting": "Clinical",
    "devices": "Apple Watch Series 4, Fitbit Versa",
    "reference": "12-lead ECG and intracardiac electrograms",
    "people": 32,
    "finding": "Wearable readings were within 10% of the reference in 89% and 86% of supraventricular tachycardia measurements, respectively. Agreement was considerably worse during ventricular tachycardia.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-42817485",
    "title": "Multi-Tier Validation of a Single-Lead Wearable ECG Signal-Processing Pipeline: Clinical Comparison and Algorithmic Benchmarking on Public Expert-Annotated Databases",
    "citation": "Vrdoljak J et al.",
    "year": 2026,
    "doi": "10.3390/s26185905",
    "pmid": "42817485",
    "url": "https://pubmed.ncbi.nlm.nih.gov/42817485/",
    "setting": "Sleep and rest",
    "devices": "Single-lead wearable ECG prototype",
    "reference": "Conventional two-electrode ECG",
    "people": null,
    "finding": "The paired clinical recordings showed minimal mean bias for heart rate in healthy adults at rest.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-42938956",
    "title": "Criterion Validity of Smartwatches for Measuring Heart Rate and Energy Expenditure During Resistance Exercise.",
    "citation": "Yun JH et al.",
    "year": 2026,
    "doi": "10.3390/bioengineering13101099",
    "pmid": "42938956",
    "url": "https://www.mdpi.com/2306-5354/13/10/1099",
    "setting": "Exercise",
    "devices": "Apple Watch Series 8, Samsung Galaxy Watch 5, Fitbit Charge 5, Garmin Vivosmart 5",
    "reference": "ECG display",
    "people": 70,
    "finding": "Galaxy Watch 5 mean absolute error was 4.50 bpm for the session average and 26.35 bpm immediately after sets.",
    "locator": "Tables 1 and 3",
    "evidence": "Published research",
    "resultsStudy": "resistance"
  },
  {
    "id": "pmid-39789790",
    "title": "Reliability and Accuracy of the Fitbit Charge 4 Photoplethysmography Heart Rate Sensor in Ecological Conditions: Validation Study.",
    "citation": "Ceugniez M et al.",
    "year": 2025,
    "doi": "10.2196/54871",
    "pmid": "39789790",
    "url": "https://pmc.ncbi.nlm.nih.gov/articles/PMC11735015/",
    "setting": "Exercise",
    "devices": "Fitbit Charge 4",
    "reference": "Polar H10",
    "people": 26,
    "finding": "Mean absolute percentage error was 1.2% running, 16.2% playing badminton and 17.5% playing soccer.",
    "locator": "Tables 2 and 3",
    "evidence": "Published research",
    "resultsStudy": "field-sports"
  },
  {
    "id": "pmid-40834291",
    "title": "Validation of nocturnal resting heart rate and heart rate variability in consumer wearables.",
    "citation": "Dial MB et al.",
    "year": 2025,
    "doi": "10.14814/phy2.70527",
    "pmid": "40834291",
    "url": "https://pubmed.ncbi.nlm.nih.gov/40834291/",
    "setting": "Sleep and rest",
    "devices": "Oura Gen 3, Oura Gen 4, Polar Grit X Pro, WHOOP 4.0",
    "reference": "Polar H10 ECG",
    "people": 13,
    "finding": "For nightly resting heart rate, mean absolute percentage error was 1.67% for Oura Gen 3, 1.94% for Gen 4 and 3.00% for WHOOP 4.0.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-39928941",
    "title": "Validity, Accuracy, and Safety Assessment of an Aerobic Interval Training Using an App-Based Prehabilitation Program (PROTEGO MAXIMA Trial) Before Major Surgery: Prospective, Interventional Pilot Study",
    "citation": "Faqar Uz Zaman SF et al.",
    "year": 2025,
    "doi": "10.2196/55298",
    "pmid": "39928941",
    "url": "https://pubmed.ncbi.nlm.nih.gov/39928941/",
    "setting": "Clinical",
    "devices": "Apple Watch Series 3, Apple Watch Series 7, Samsung Galaxy Watch 4",
    "reference": "Standard ECG",
    "people": 75,
    "finding": "Compared three watches paired with four phone configurations. Mean heart-rate differences from ECG were within 5 bpm in treadmill tests.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-41335886",
    "title": "Hearable Heartbeats: Recording the Heart Rate from the Ear",
    "citation": "Gaardbaek B et al.",
    "year": 2025,
    "doi": "10.1109/embc58623.2025.11254754",
    "pmid": "41335886",
    "url": "https://pubmed.ncbi.nlm.nih.gov/41335886/",
    "setting": "Sleep and rest",
    "devices": "In-ear body-coupled microphone prototype",
    "reference": "ECG",
    "people": 10,
    "finding": "Nine of 19 recorded ears had root mean square error below 4 bpm. Four of ten people had low detection and larger errors.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-41027030",
    "title": "The Validation and Accuracy of Wearable Heart Rate Trackers in Children With Heart Disease: Prospective Cohort Study.",
    "citation": "Hardon HJ et al.",
    "year": 2025,
    "doi": "10.2196/70835",
    "pmid": "41027030",
    "url": "https://pubmed.ncbi.nlm.nih.gov/41027030/",
    "setting": "Clinical",
    "devices": "Corsano CardioWatch, Hexoskin",
    "reference": "24-hour Holter ECG",
    "people": null,
    "finding": "Mean share within 10% of Holter was 84.8% for the bracelet in 31 children and 87.4% for the shirt in 36 children.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-41209591",
    "title": "Validation of heart rate measured by the consumer-level wearable device Fitbit: a cross-sectional observational study.",
    "citation": "Higuchi D et al.",
    "year": 2025,
    "doi": "10.1589/jpts.37.561",
    "pmid": "41209591",
    "url": "https://pubmed.ncbi.nlm.nih.gov/41209591/",
    "setting": "Exercise",
    "devices": "Fitbit Inspire 3",
    "reference": "ECG",
    "people": 22,
    "finding": "Fitbit read about 3 bpm low on average. Absolute percent error was under 10% for most of the rest and exercise tasks.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-39928630",
    "title": "Validity of heart rate measurements in wrist-based monitors across skin tones during exercise",
    "citation": "Hung SH et al.",
    "year": 2025,
    "doi": "10.1371/journal.pone.0318724",
    "pmid": "39928630",
    "url": "https://pubmed.ncbi.nlm.nih.gov/39928630/",
    "setting": "Exercise",
    "devices": "Fitbit Charge 5",
    "reference": "Polar H10",
    "people": 25,
    "finding": "During recumbent cycling, error increased with exercise intensity in participants with darker skin tones.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-40212900",
    "title": "Investigating the accuracy of Garmin PPG sensors on differing skin types based on the Fitzpatrick scale: cross-sectional comparison study",
    "citation": "Icenhower A et al.",
    "year": 2025,
    "doi": "10.3389/fdgth.2025.1553565",
    "pmid": "40212900",
    "url": "https://pubmed.ncbi.nlm.nih.gov/40212900/",
    "setting": "Exercise",
    "devices": "Garmin Forerunner 45",
    "reference": "Polar H10",
    "people": 29,
    "finding": "The wrist reading lagged the reference in the first ramp-up phase. The study did not find a significant main effect of Fitzpatrick skin type.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-40196089",
    "title": "Evaluation of Telemetric Single-Lead Cardiac Transmitter and Apple Watch for Heart Rate Monitoring: Implications for Heart Failure Management in Home Care.",
    "citation": "Imai H et al.",
    "year": 2025,
    "doi": "10.7759/cureus.80232",
    "pmid": "40196089",
    "url": "https://pubmed.ncbi.nlm.nih.gov/40196089/",
    "setting": "Clinical",
    "devices": "Apple Watch Series 7, Cocoron",
    "reference": "Wireless reference ECG",
    "people": null,
    "finding": "The Cocoron single-lead ECG wearable had lower mean absolute percentage error than Apple Watch in this comparison.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-40938218",
    "title": "Does a polar chest strap pair with an Apple Watch more accurately than an Apple Watch alone on low, moderate, and high exercise intensities? A cross-sectional study",
    "citation": "Khushhal AA",
    "year": 2025,
    "doi": "10.23736/s0022-4707.25.16270-1",
    "pmid": "40938218",
    "url": "https://pubmed.ncbi.nlm.nih.gov/40938218/",
    "setting": "Exercise",
    "devices": "Apple Watch",
    "reference": "Polar chest strap",
    "people": 30,
    "finding": "Watch and strap correlations were 0.96 during high-intensity treadmill exercise and 0.99 during high-intensity cycling.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-41052425",
    "title": "Validity of Heart Rate Measurement Using Wearable Devices During Cardiopulmonary Exercise Testing in Patients With Cardiovascular Disease: Prospective Pilot Validation Study.",
    "citation": "Kitagaki K et al.",
    "year": 2025,
    "doi": "10.2196/77911",
    "pmid": "41052425",
    "url": "https://pubmed.ncbi.nlm.nih.gov/41052425/",
    "setting": "Clinical",
    "devices": "Fitbit Inspire 3",
    "reference": "ECG",
    "people": 30,
    "finding": "Mean absolute percentage error was 5.40% across the clinical exercise test. Underestimates were more frequent above the anaerobic threshold.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-40984067",
    "title": "Laboratory-Based Wearable Heart Rate Data Efficacies for Informing Real-world Department of Defense Wearables Decisions",
    "citation": "Knodel NB et al.",
    "year": 2025,
    "doi": "10.1093/milmed/usaf267",
    "pmid": "40984067",
    "url": "https://pubmed.ncbi.nlm.nih.gov/40984067/",
    "setting": "Exercise",
    "devices": "Garmin fēnix 6X Pro Solar",
    "reference": "Polar H10",
    "people": null,
    "finding": "Accuracy was similar in lab tests and obstacle races at matched levels of movement and intensity. It fell during more vigorous and dynamic activity.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-40735859",
    "title": "Validation of the Fitbit Charge 5 for the Detection of Heart Rate and Electrodermal Activity",
    "citation": "Ko K et al.",
    "year": 2025,
    "doi": "10.1111/psyp.70116",
    "pmid": "40735859",
    "url": "https://pubmed.ncbi.nlm.nih.gov/40735859/",
    "setting": "Sleep and rest",
    "devices": "Fitbit Charge 5",
    "reference": "Equivital EQ02 ECG",
    "people": 55,
    "finding": "During social stress and reading tasks, Fitbit tended to read 24 to 32 bpm lower than Equivital. Intraclass correlations ranged from 0.53 to 0.72.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-40227137",
    "title": "Validation of polar verity sense for heart rate monitoring during school-based high-intensity interval training in adolescents.",
    "citation": "Liu Y et al.",
    "year": 2025,
    "doi": "10.1080/02640414.2025.2491163",
    "pmid": "40227137",
    "url": "https://pubmed.ncbi.nlm.nih.gov/40227137/",
    "setting": "Exercise",
    "devices": "Polar Verity Sense",
    "reference": "Polar H10",
    "people": 39,
    "finding": "In six minutes of school-based resistance intervals, absolute error averaged 4 bpm and 2.8%.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-40017799",
    "title": "Laboratory comparison of consumer-grade and research-established wearables for monitoring heart rate, body temperature, and physical acitivity in sub-Saharan Africa.",
    "citation": "Mendt S et al.",
    "year": 2025,
    "doi": "10.3389/fphys.2025.1491401",
    "pmid": "40017799",
    "url": "https://pubmed.ncbi.nlm.nih.gov/40017799/",
    "setting": "Exercise",
    "devices": "Withings Pulse HR",
    "reference": "Bittium Faros 180 chest ECG",
    "people": 22,
    "finding": "While sitting, standing or walking slowly, absolute bias was at most 3.1 bpm, with correlations at least 0.82. At faster treadmill speeds, correlations were 0.33 or lower.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-41516615",
    "title": "Impact of Anatomical Placement on the Accuracy of Wearable Heart Rate Monitors During Rest and Various Exercise Intensities.",
    "citation": "Moghaddam M et al.",
    "year": 2025,
    "doi": "10.3390/s26010176",
    "pmid": "41516615",
    "url": "https://pubmed.ncbi.nlm.nih.gov/41516615/",
    "setting": "Exercise",
    "devices": "WHOOP 4.0, Polar Verity Sense, Garmin Forerunner",
    "reference": "Polar H10",
    "people": 28,
    "finding": "All placements had concordance above 0.99 at rest. In the warm-up, upper-arm WHOOP agreed more closely with the strap than wrist WHOOP.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-40063512",
    "title": "Assessing the Accuracy of Fitness Smartwatch Data for Cardiovascular and Physical Activity Monitoring: A Validation Study in Digital Health",
    "citation": "Mohamad Matrol AA et al.",
    "year": 2025,
    "doi": "10.3791/67674",
    "pmid": "40063512",
    "url": "https://pubmed.ncbi.nlm.nih.gov/40063512/",
    "setting": "Sleep and rest",
    "devices": "Low-cost fitness smartwatch",
    "reference": "Polysomnography",
    "people": 26,
    "finding": "Mean overnight heart rate showed no significant average difference. The smartwatch overestimated the overnight maximum.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-41305102",
    "title": "The Effect of Tattoos on Heart Rate Validity in the Polar Verity Sense Commercial Wearable Device.",
    "citation": "Navalta JW et al.",
    "year": 2025,
    "doi": "10.3390/s25226896",
    "pmid": "41305102",
    "url": "https://pmc.ncbi.nlm.nih.gov/articles/PMC12656504/",
    "setting": "Exercise",
    "devices": "Polar Verity Sense",
    "reference": "Polar H10",
    "people": 25,
    "finding": "At rest, mean absolute percentage error was 22.9% over tattooed skin and 2.9% over nearby uncovered skin. On tattooed skin it was 7.5% walking and 5.1% running.",
    "locator": "Table 1",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-39294928",
    "title": "Validity of Wrist-Worn Activity Tracker Heart Rate Detection in Fontan Patients during Exercise",
    "citation": "Pierick AR et al.",
    "year": 2025,
    "doi": "10.1249/mss.0000000000003567",
    "pmid": "39294928",
    "url": "https://pubmed.ncbi.nlm.nih.gov/39294928/",
    "setting": "Clinical",
    "devices": "Garmin and Fitbit wrist trackers",
    "reference": "Exercise-test ECG",
    "people": 47,
    "finding": "In people with Fontan circulation, mean absolute percentage error was below 10% at most sampled points during supervised exercise testing.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-40615117",
    "title": "Limited Validity of the Low-Cost Coospo H808S Heart-Rate Monitor Compared to the Polar H10.",
    "citation": "Protzen G et al.",
    "year": 2025,
    "doi": "10.1123/ijspp.2025-0126",
    "pmid": "40615117",
    "url": "https://pubmed.ncbi.nlm.nih.gov/40615117/",
    "setting": "Exercise",
    "devices": "Coospo H808S",
    "reference": "Polar H10",
    "people": 15,
    "finding": "Supine heart-rate agreement was high. The authors found larger discrepancies in heart-rate variability during easy running.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-40363363",
    "title": "Validation of an Open-Source Smartwatch for Continuous Monitoring of Physical Activity and Heart Rate in Adults.",
    "citation": "Ravanelli N et al.",
    "year": 2025,
    "doi": "10.3390/s25092926",
    "pmid": "40363363",
    "url": "https://pubmed.ncbi.nlm.nih.gov/40363363/",
    "setting": "Daily life",
    "devices": "Bangle.js 2",
    "reference": "Polar H10",
    "people": 47,
    "finding": "Concordance for minute-averaged heart rate in daily life was 0.78 for the open-source watch.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "10-1177-17543371231165102",
    "title": "Concurrent validity of the Polar Precision Prime photoplethysmographic system to measure heart rate during a tennis training session",
    "citation": "Ruiz-Malagón EJ et al.",
    "year": 2025,
    "doi": "10.1177/17543371231165102",
    "pmid": null,
    "url": "https://doi.org/10.1177/17543371231165102",
    "setting": "Exercise",
    "devices": "Polar Ignite",
    "reference": "Polar H10 recorded on Polar V800",
    "people": 40,
    "finding": "Mean absolute percentage error was below 5.03% across the tennis session parts and ten-second intervals. The reported mean bias was −2.41 bpm for the ten-second intervals.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-40732604",
    "title": "Experimental Analysis on the Effect of Contact Pressure and Activity Level as Influencing Factors in PPG Sensor Performance",
    "citation": "Scardulla F et al.",
    "year": 2025,
    "doi": "10.3390/s25144477",
    "pmid": "40732604",
    "url": "https://pubmed.ncbi.nlm.nih.gov/40732604/",
    "setting": "Exercise",
    "devices": "Pressure-controlled wrist PPG prototype",
    "reference": "ECG-based monitor",
    "people": 25,
    "finding": "At the best fixed sensor pressure in this experiment, mean absolute percentage error ranged from 3.36% to 6.83% across treadmill speeds.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-40116771",
    "title": "Wrist-Worn and Arm-Worn Wearables for Monitoring Heart Rate During Sedentary and Light-to-Vigorous Physical Activities: Device Validation Study.",
    "citation": "Schweizer T et al.",
    "year": 2025,
    "doi": "10.2196/67110",
    "pmid": "40116771",
    "url": "https://pubmed.ncbi.nlm.nih.gov/40116771/",
    "setting": "Exercise",
    "devices": "Polar Verity Sense, Polar Vantage V2",
    "reference": "Polar H10",
    "people": 16,
    "finding": "Across this nine-activity protocol, absolute error averaged 1.43 bpm at the upper-arm Verity Sense and 6.41 bpm on the Vantage V2 worn on the nondominant wrist.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-39905563",
    "title": "Quality in Question: Assessing the Accuracy of Four Heart Rate Wearables and the Implications for Psychophysiological Research",
    "citation": "Sinichi M et al.",
    "year": 2025,
    "doi": "10.1111/psyp.70004",
    "pmid": "39905563",
    "url": "https://pubmed.ncbi.nlm.nih.gov/39905563/",
    "setting": "Exercise",
    "devices": "Four optical and ECG wearables",
    "reference": "VU-AMS ECG",
    "people": 40,
    "finding": "Agreement of the optical devices fell as the protocol moved from seated baseline to tasks with more movement.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-40807699",
    "title": "Estimating Heart Rate from Inertial Sensors Embedded in Smart Eyewear: A Validation Study.",
    "citation": "Solbiati S et al.",
    "year": 2025,
    "doi": "10.3390/s25154531",
    "pmid": "40807699",
    "url": "https://pubmed.ncbi.nlm.nih.gov/40807699/",
    "setting": "Sleep and rest",
    "devices": "SmartEW eyewear, Garmin Venu 3",
    "reference": "Movesense Flash ECG",
    "people": 30,
    "finding": "With the chosen signal-quality filter, 95% of retained eyewear readings were within 5 bpm. Coverage at that cutoff was 80%.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-41157371",
    "title": "Accuracy of Heart Rate Measurement Under Transient States: A Validation Study of Wearables for Real-Life Monitoring.",
    "citation": "Van Oost CN et al.",
    "year": 2025,
    "doi": "10.3390/s25206319",
    "pmid": "41157371",
    "url": "https://www.mdpi.com/1424-8220/25/20/6319",
    "setting": "Exercise",
    "devices": "Fitbit Charge 5, Fitbit Sense 2, Garmin Vivosmart 4, WHOOP 4.0, Withings ScanWatch, Zephyr BioHarness, Empatica EmbracePlus",
    "reference": "12-lead ECG",
    "people": 23,
    "finding": "Garmin Vivosmart 4 had 4.12% median absolute percentage error at per-second matches. Roughly 93% of reference points went unmatched at that resolution.",
    "locator": "Table 3",
    "evidence": "Published research",
    "resultsStudy": "transitions"
  },
  {
    "id": "pmid-40547435",
    "title": "Continuous heart rate measurements in patients with cardiac disease: Device comparison and development of a novel artefact removal procedure.",
    "citation": "Vermunicht P et al.",
    "year": 2025,
    "doi": "10.1177/20552076251337598",
    "pmid": "40547435",
    "url": "https://pubmed.ncbi.nlm.nih.gov/40547435/",
    "setting": "Clinical",
    "devices": "Fitbit Inspire 2, Polar H10",
    "reference": "Holter ECG",
    "people": 15,
    "finding": "Over daily life in cardiac patients, mean absolute error was 3.4 bpm for the Polar chest strap and 8.3 bpm for Fitbit before applying the study's artifact removal procedure.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-40605982",
    "title": "Validation of the EmotiBit wearable sensor for heart-based measures under varying workload conditions",
    "citation": "Vorreuther A et al.",
    "year": 2025,
    "doi": "10.3389/fnrgo.2025.1585469",
    "pmid": "40605982",
    "url": "https://pubmed.ncbi.nlm.nih.gov/40605982/",
    "setting": "Sleep and rest",
    "devices": "EmotiBit",
    "reference": "BITalino PsychoBit ECG",
    "people": 15,
    "finding": "Heart rate differed by about 1 to 2 bpm on average during a cognitive workload task.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-40335520",
    "title": "Validity of Hera Leto consumer earbuds for heart rate monitoring during stationary cycling.",
    "citation": "Yang J et al.",
    "year": 2025,
    "doi": "10.1038/s41598-025-00559-5",
    "pmid": "40335520",
    "url": "https://pubmed.ncbi.nlm.nih.gov/40335520/",
    "setting": "Exercise",
    "devices": "Hera Leto earbuds, Polar Verity Sense, Polar Vantage V",
    "reference": "Polar H10",
    "people": null,
    "finding": "Mean absolute error was 2 bpm for the earbuds and 4 bpm for each Polar optical device during stationary cycling.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-38377012",
    "title": "Development and Calibration of a PATCH Device for Monitoring Children's Heart Rate and Acceleration",
    "citation": "Armstrong B et al.",
    "year": 2024,
    "doi": "10.1249/mss.0000000000003404",
    "pmid": "38377012",
    "url": "https://pubmed.ncbi.nlm.nih.gov/38377012/",
    "setting": "Exercise",
    "devices": "PATCH pediatric heart-rate monitor",
    "reference": "Actiheart ECG",
    "people": 63,
    "finding": "In children ages 3 to 8, mean absolute error was 6.67 bpm and average bias was +2.26 bpm.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-39728259",
    "title": "Accuracy of the Apple Watch Series 9 for Measures of Energy Expenditure and Heart Rate at Rest and During Exercise: Impact of Skin Pigmentation.",
    "citation": "Chase SE et al.",
    "year": 2024,
    "doi": "10.3390/jfmk9040275",
    "pmid": "39728259",
    "url": "https://pubmed.ncbi.nlm.nih.gov/39728259/",
    "setting": "Exercise",
    "devices": "Apple Watch Series 9",
    "reference": "Polar H7",
    "people": 30,
    "finding": "During this short treadmill protocol, heart-rate agreement varied more in the group with darker skin pigmentation.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-38713497",
    "title": "Accuracy of the Apple Watch Series 4 and Fitbit Versa for Assessing Energy Expenditure and Heart Rate of Wheelchair Users During Treadmill Wheelchair Propulsion: Cross-sectional Study",
    "citation": "Danielsson ML et al.",
    "year": 2024,
    "doi": "10.2196/52312",
    "pmid": "38713497",
    "url": "https://formative.jmir.org/2024/1/e52312",
    "setting": "Exercise",
    "devices": "Apple Watch Series 4, Fitbit Versa",
    "reference": "Polar H10",
    "people": 40,
    "finding": "Across stages and inclines, mean absolute percentage error in wheelchair users was 8.5% for Apple Watch and 17.4% for Fitbit Versa.",
    "locator": "Results, Absolute Agreement",
    "evidence": "Published research",
    "resultsStudy": "wheelchair"
  },
  {
    "id": "pmid-38450553",
    "title": "Assessment of Fitbit Charge 4 for sleep stage and heart rate monitoring against polysomnography and during home monitoring in Huntington's disease",
    "citation": "Doheny EP et al.",
    "year": 2024,
    "doi": "10.5664/jcsm.11098",
    "pmid": "38450553",
    "url": "https://pubmed.ncbi.nlm.nih.gov/38450553/",
    "setting": "Sleep and rest",
    "devices": "Fitbit Charge 4",
    "reference": "Polysomnography ECG",
    "people": 10,
    "finding": "For participants with Huntington’s disease who spent a night in a sleep lab, Fitbit averaged 1.16 bpm of absolute heart-rate error.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-39504450",
    "title": "Validity of a Consumer-Based Wearable to Measure Clinical Parameters in Patients With Chronic Obstructive Pulmonary Disease and Healthy Controls: Observational Study",
    "citation": "Hermans F et al.",
    "year": 2024,
    "doi": "10.2196/56027",
    "pmid": "39504450",
    "url": "https://pubmed.ncbi.nlm.nih.gov/39504450/",
    "setting": "Clinical",
    "devices": "Fitbit Charge 4",
    "reference": "Polar H10",
    "people": 45,
    "finding": "Resting heart-rate agreement was similar in people with COPD and healthy controls, with intraclass correlations of 0.80 and 0.79, respectively.",
    "locator": "Table 2 and Figure 3",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-38528248",
    "title": "From lab to life: Evaluating the reliability and validity of psychophysiological data from wearable devices in laboratory and ambulatory settings",
    "citation": "Hu X et al.",
    "year": 2024,
    "doi": "10.3758/s13428-024-02387-3",
    "pmid": "38528248",
    "url": "https://pubmed.ncbi.nlm.nih.gov/38528248/",
    "setting": "Daily life",
    "devices": "Movisens EcgMove4, Empatica E4",
    "reference": "MindWare laboratory ECG",
    "people": 67,
    "finding": "In the lab, heart-rate intraclass correlations were 0.98 to 1.00. Less wearable data met signal-quality rules during the separate daily-life testing.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-37973701",
    "title": "Evaluation of Wrist-Worn Photoplethysmography Trackers with an Electrocardiogram in Patients with Ischemic Heart Disease: A Validation Study",
    "citation": "Ibrahim NS et al.",
    "year": 2024,
    "doi": "10.1007/s13239-023-00693-z",
    "pmid": "37973701",
    "url": "https://pubmed.ncbi.nlm.nih.gov/37973701/",
    "setting": "Clinical",
    "devices": "Amazfit Cor, Amazfit Bip",
    "reference": "12-lead ECG",
    "people": 51,
    "finding": "Absolute percentage error stayed within 10% in the sampled treadmill stages. Accuracy fell as exercise intensified and recovered afterward.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-39066072",
    "title": "Validity of Current Smartwatches for Triathlon Training: How Accurate Are Heart Rate, Distance, and Swimming Readings?",
    "citation": "Jacko T et al.",
    "year": 2024,
    "doi": "10.3390/s24144675",
    "pmid": "39066072",
    "url": "https://pubmed.ncbi.nlm.nih.gov/39066072/",
    "setting": "Exercise",
    "devices": "Ten triathlon smartwatches",
    "reference": "ECG chest strap",
    "people": 30,
    "finding": "Mean absolute percentage error for average heart rate ranged from 3.1% to 8.3% in treadmill intervals.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-39362983",
    "title": "Accuracy of smartwatches for the remote assessment of exercise capacity.",
    "citation": "Jamieson A et al.",
    "year": 2024,
    "doi": "10.1038/s41598-024-74140-x",
    "pmid": "39362983",
    "url": "https://pubmed.ncbi.nlm.nih.gov/39362983/",
    "setting": "Exercise",
    "devices": "Garmin Vivoactive 4, Fitbit Sense",
    "reference": "ECG",
    "people": 16,
    "finding": "Median absolute percentage error was at most 3% at rest and recovery and reached about 7% for Garmin and 12% for Fitbit at peak exercise.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-38496326",
    "title": "Accuracy of Apple Watch to Measure Cardiovascular Indices in Patients with Chronic Diseases: A Cross Sectional Study",
    "citation": "Khushhal AA et al.",
    "year": 2024,
    "doi": "10.2147/jmdh.s449071",
    "pmid": "38496326",
    "url": "https://pubmed.ncbi.nlm.nih.gov/38496326/",
    "setting": "Clinical",
    "devices": "Apple Watch",
    "reference": "Polar ECG chest strap",
    "people": 41,
    "finding": "In adults with chronic conditions, the authors found that exercise and recovery heart rates tracked the chest strap closely.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-39686012",
    "title": "Deriving Accurate Nocturnal Heart Rate, rMSSD and Frequency HRV from the Oura Ring.",
    "citation": "Liang T et al.",
    "year": 2024,
    "doi": "10.3390/s24237475",
    "pmid": "39686012",
    "url": "https://pubmed.ncbi.nlm.nih.gov/39686012/",
    "setting": "Sleep and rest",
    "devices": "Oura Ring Gen 3",
    "reference": "Overnight ECG",
    "people": 114,
    "finding": "The authors found strong agreement for nocturnal heart rate across both age groups. Higher quality thresholds and longer windows improved agreement.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-39661434",
    "title": "Validation of a Wearable Sensor Prototype for Measuring Heart Rate to Prescribe Physical Activity: Cross-Sectional Exploratory Study",
    "citation": "Loro FL et al.",
    "year": 2024,
    "doi": "10.2196/57373",
    "pmid": "39661434",
    "url": "https://pubmed.ncbi.nlm.nih.gov/39661434/",
    "setting": "Exercise",
    "devices": "Wearable optical sensor prototype",
    "reference": "Polar H10",
    "people": null,
    "finding": "Absolute mean differences were 2.6 bpm at rest, 4.1 bpm at maximum effort and 2.5 bpm in recovery during a shuttle-walk test.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "10-3390-app142411872",
    "title": "Heart Rate Measurement Accuracy During Intermittent Efforts Under Laboratory Conditions: A Comparative Analysis Between Chest Straps and Armband",
    "citation": "Marzano-Felisatti JM et al.",
    "year": 2024,
    "doi": "10.3390/app142411872",
    "pmid": null,
    "url": "https://doi.org/10.3390/app142411872",
    "setting": "Exercise",
    "devices": "Coospo H6, Coospo HW807",
    "reference": "Garmin HRM-Dual ECG chest strap",
    "people": 30,
    "finding": "During the harder cycling intervals the Coospo armband averaged about 5 bpm above the chest straps.",
    "locator": "Results and conclusions",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-40039189",
    "title": "Robust Heart Rate Detection via Multi-Site Photoplethysmography",
    "citation": "Meier M et al.",
    "year": 2024,
    "doi": "10.1109/embc53108.2024.10782155",
    "pmid": "40039189",
    "url": "https://pubmed.ncbi.nlm.nih.gov/40039189/",
    "setting": "Daily life",
    "devices": "Multi-site PPG sensor prototype",
    "reference": "Simultaneous ECG",
    "people": 14,
    "finding": "Combining optical sites reduced mean heart-rate error from 4.4 bpm at the best single site to 2.4 bpm in the prototype analysis.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-38246569",
    "title": "\"But for the blind spot\": Accuracy and diagnostic performance of smart watch cardiac features in pediatric patients",
    "citation": "Nash D et al.",
    "year": 2024,
    "doi": "10.1016/j.hrthm.2024.01.021",
    "pmid": "38246569",
    "url": "https://pubmed.ncbi.nlm.nih.gov/38246569/",
    "setting": "Clinical",
    "devices": "Apple Watch",
    "reference": "Telemetry, electrophysiology or exercise-test ECG",
    "people": 80,
    "finding": "Intraclass correlation was 0.99 in sinus rhythm and 0.24 to 0.27 in tachyarrhythmia, when the watch tended to undercount.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-39508366",
    "title": "Validity of Four Consumer-Grade Optical Heart Rate Sensors for Assessing Volume and Intensity Distribution of Physical Activity.",
    "citation": "Neudorfer M et al.",
    "year": 2024,
    "doi": "10.1111/sms.14756",
    "pmid": "39508366",
    "url": "https://doi.org/10.1111/sms.14756",
    "setting": "Daily life",
    "devices": "Garmin Venu 2S, Polar Vantage M2, Polar Verity Sense, Scosche Rhythm24",
    "reference": "Medical-grade ECG",
    "people": 32,
    "finding": "The source reported mean absolute percentage errors from 2.2% to 4.7% across activities. Vora also reanalyzed the released lab and daily-life data.",
    "locator": "Published results and public paired recordings",
    "evidence": "Published research",
    "resultsStudy": "all-day"
  },
  {
    "id": "pmid-39409260",
    "title": "The Validity of Apple Watch Series 9 and Ultra 2 for Serial Measurements of Heart Rate Variability and Resting Heart Rate.",
    "citation": "O'Grady B et al.",
    "year": 2024,
    "doi": "10.3390/s24196220",
    "pmid": "39409260",
    "url": "https://pubmed.ncbi.nlm.nih.gov/39409260/",
    "setting": "Sleep and rest",
    "devices": "Apple Watch Series 9 and Ultra 2",
    "reference": "Polar H10 with Kubios",
    "people": 39,
    "finding": "For resting heart rate, the reported mean difference was −0.08 bpm, with 3.73 bpm mean absolute error.",
    "locator": "Table 1 and abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-38900505",
    "title": "Heart Rate Monitoring Among Breast Cancer Survivors: Quantitative Study of Device Agreement in a Community-Based Exercise Program",
    "citation": "Page LL et al.",
    "year": 2024,
    "doi": "10.2196/51210",
    "pmid": "38900505",
    "url": "https://pubmed.ncbi.nlm.nih.gov/38900505/",
    "setting": "Clinical",
    "devices": "Fitbit Inspire HR",
    "reference": "Polar H10",
    "people": 14,
    "finding": "Agreement with the strap was highest during seated recovery (concordance 0.89) and lowest during warm-up (0.39).",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-39517723",
    "title": "Assessment of Physiological Signals from Photoplethysmography Sensors Compared to an Electrocardiogram Sensor: A Validation Study in Daily Life",
    "citation": "Rehman RZU et al.",
    "year": 2024,
    "doi": "10.3390/s24216826",
    "pmid": "39517723",
    "url": "https://www.mdpi.com/1424-8220/24/21/6826",
    "setting": "Daily life",
    "devices": "WHOOP 4.0, Corsano CardioWatch 287-1B",
    "reference": "VitalPatch ECG",
    "people": 25,
    "finding": "In ten days of daily wear, both optical devices had less than 1 bpm of mean absolute heart-rate error during sleep. Corsano raw PPG and processed WHOOP intervals were analyzed.",
    "locator": "Table 5",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-39409419",
    "title": "Validity and Reliability of Wearable Sensors for Continuous Postoperative Vital Signs Monitoring in Patients Recovering from Trauma Surgery",
    "citation": "van Melzen R et al.",
    "year": 2024,
    "doi": "10.3390/s24196379",
    "pmid": "39409419",
    "url": "https://pubmed.ncbi.nlm.nih.gov/39409419/",
    "setting": "Clinical",
    "devices": "Wearable ECG and PPG sensors",
    "reference": "Post-anesthesia bedside monitoring",
    "people": 60,
    "finding": "For heart rate, the wearable ECG met the study’s agreement limits. The wearable optical sensor did not.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-39367187",
    "title": "Validation and user experience of a dry electrode based Health Patch for heart rate and respiration rate monitoring",
    "citation": "Wei JCJ et al.",
    "year": 2024,
    "doi": "10.1038/s41598-024-73557-8",
    "pmid": "39367187",
    "url": "https://pubmed.ncbi.nlm.nih.gov/39367187/",
    "setting": "Exercise",
    "devices": "Dry-electrode Health Patch",
    "reference": "Shimmer3 ECG",
    "people": 25,
    "finding": "The dry-electrode patch showed close heart-rate agreement during rest, squats and stationary cycling.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-36805933",
    "title": "Parameters Influencing the Accuracy of a Wrist Photoplethysmography Heart-Rate Monitor (Polar Unite) During Exercise.",
    "citation": "Bretonneau Q et al.",
    "year": 2023,
    "doi": "10.1123/ijspp.2022-0288",
    "pmid": "36805933",
    "url": "https://pubmed.ncbi.nlm.nih.gov/36805933/",
    "setting": "Exercise",
    "devices": "Polar Unite",
    "reference": "10-lead ECG",
    "people": 30,
    "finding": "In cycling, the coefficient of variation went from 20.3% with a normally fitted band to 6.2% with the tighter fit tested.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-38287935",
    "title": "Assessing the Validity of Several Heart Rate Monitors in Wearable Technology While Mountain Biking.",
    "citation": "Carrier B et al.",
    "year": 2023,
    "doi": "10.70252/pmwe7524",
    "pmid": "38287935",
    "url": "https://pubmed.ncbi.nlm.nih.gov/38287935/",
    "setting": "Exercise",
    "devices": "Suunto Spartan Sport with chest strap and other tested wearables",
    "reference": "Polar H7",
    "people": 20,
    "finding": "Mean absolute percentage error was 0.66% for the Suunto chest strap setup over both mountain biking trials.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-38875680",
    "title": "Measuring Heart Rate Accurately in Patients With Parkinson Disease During Intense Exercise: Usability Study of Fitbit Charge 4.",
    "citation": "Colonna G et al.",
    "year": 2023,
    "doi": "10.2196/51515",
    "pmid": "38875680",
    "url": "https://pubmed.ncbi.nlm.nih.gov/38875680/",
    "setting": "Clinical",
    "devices": "Fitbit Charge 4",
    "reference": "Polar H10",
    "people": 11,
    "finding": "In participants with Parkinson disease, Fitbit read 1.68 bpm high at rest and 6.29 bpm high during intense exercise.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-38005593",
    "title": "Sensorized T-Shirt with Intarsia-Knitted Conductive Textile Integrated Interconnections: Performance Assessment of Cardiac Measurements during Daily Living Activities",
    "citation": "Hafid A et al.",
    "year": 2023,
    "doi": "10.3390/s23229208",
    "pmid": "38005593",
    "url": "https://pubmed.ncbi.nlm.nih.gov/38005593/",
    "setting": "Daily life",
    "devices": "Sensorized textile T-shirt",
    "reference": "ECG chest strap",
    "people": null,
    "finding": "Mean absolute percentage error averaged below 3% across the tested stationary and moving tasks.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-34957939",
    "title": "Wrist-worn devices for the measurement of heart rate and energy expenditure: A validation study for the Apple Watch 6, Polar Vantage V and Fitbit Sense.",
    "citation": "Hajj-Boutros G et al.",
    "year": 2023,
    "doi": "10.1080/17461391.2021.2023656",
    "pmid": "34957939",
    "url": "https://pubmed.ncbi.nlm.nih.gov/34957939/",
    "setting": "Exercise",
    "devices": "Apple Watch Series 6, Polar Vantage V, Fitbit Sense",
    "reference": "Polar H10",
    "people": 60,
    "finding": "The coefficient of variation for heart-rate error was under 5% for Apple Watch in each of five activities. Polar and Fitbit varied more by activity.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-36748247",
    "title": "Accuracy of continuous photoplethysmography-based 1 min mean heart rate assessment during atrial fibrillation.",
    "citation": "Hermans ANL et al.",
    "year": 2023,
    "doi": "10.1093/europace/euad011",
    "pmid": "36748247",
    "url": "https://pubmed.ncbi.nlm.nih.gov/36748247/",
    "setting": "Clinical",
    "devices": "Wrist optical smartwatch",
    "reference": "Holter ECG",
    "people": 50,
    "finding": "One-minute heart rates were within 10% of ECG in 93.7% of usable pairs during persistent atrial fibrillation. Only 60% of the analyzed period supported the comparison.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-37648537",
    "title": "Continuous Monitoring of Changes in Heart Rate during the Periprocedural Course of Carotid Artery Stenting Using a Wearable Device: A Prospective Observational Study",
    "citation": "Hirai K et al.",
    "year": 2023,
    "doi": "10.2176/jns-nmc.2023-0093",
    "pmid": "37648537",
    "url": "https://pubmed.ncbi.nlm.nih.gov/37648537/",
    "setting": "Clinical",
    "devices": "Wearable pulse monitor",
    "reference": "ECG",
    "people": 12,
    "finding": "During carotid artery stenting, the wearable averaged 1.12 bpm below ECG.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-37536665",
    "title": "Validation of Wearable Digital Devices for Heart Rate Measurement During Exercise Test in Patients With Coronary Artery Disease.",
    "citation": "Kim C et al.",
    "year": 2023,
    "doi": "10.5535/arm.23019",
    "pmid": "37536665",
    "url": "https://pubmed.ncbi.nlm.nih.gov/37536665/",
    "setting": "Clinical",
    "devices": "Apple Watch Series 7, Galaxy Watch 4, Mobicare 200",
    "reference": "12-lead ECG",
    "people": 44,
    "finding": "Mean absolute percentage error was under 2% for all three devices during the coronary artery disease exercise-test protocol.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-36829748",
    "title": "Are Activity Wrist-Worn Devices Accurate for Determining Heart Rate during Intense Exercise?",
    "citation": "Martín-Escudero P et al.",
    "year": 2023,
    "doi": "10.3390/bioengineering10020254",
    "pmid": "36829748",
    "url": "https://pubmed.ncbi.nlm.nih.gov/36829748/",
    "setting": "Exercise",
    "devices": "Fitbit Charge, Apple Watch, TomTom Runner Cardio, Samsung Gear S2",
    "reference": "Continuous ECG",
    "people": 8,
    "finding": "Fitbit and Samsung tended to underestimate heart rate at high effort in this small maximal exercise test.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-37430546",
    "title": "Accuracy of a Smartwatch to Assess Heart Rate Monitoring and Atrial Fibrillation in Stroke Patients.",
    "citation": "Meza C et al.",
    "year": 2023,
    "doi": "10.3390/s23104632",
    "pmid": "37430546",
    "url": "https://pubmed.ncbi.nlm.nih.gov/37430546/",
    "setting": "Clinical",
    "devices": "Fitbit Charge 5",
    "reference": "Continuous ECG monitoring",
    "people": 70,
    "finding": "In stroke patients, the concordance coefficient was 0.791 during sinus rhythm and 0.211 during atrial fibrillation. Mean absolute percentage error was 16.48% during atrial fibrillation.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-36862131",
    "title": "Commercial Smart Watches and Heart Rate Monitors: A Concurrent Validity Analysis",
    "citation": "Montalvo S et al.",
    "year": 2023,
    "doi": "10.1519/jsc.0000000000004482",
    "pmid": "36862131",
    "url": "https://pubmed.ncbi.nlm.nih.gov/36862131/",
    "setting": "Exercise",
    "devices": "Apple Watch Series 6, Apple Watch Series 7, Polar H10",
    "reference": "12-lead ECG",
    "people": 44,
    "finding": "Both watches were closer to ECG at lower movement speeds than at higher treadmill speeds. The researchers also tested Polar H10 directly against ECG.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-37474743",
    "title": "Heart rate processing algorithms and exercise duration on reliability and validity decisions in biceps-worn Polar Verity Sense and OH1 wearables",
    "citation": "Navalta JW et al.",
    "year": 2023,
    "doi": "10.1038/s41598-023-38329-w",
    "pmid": "37474743",
    "url": "https://pubmed.ncbi.nlm.nih.gov/37474743/",
    "setting": "Exercise",
    "devices": "Polar Verity Sense, Polar OH1",
    "reference": "Polar H10",
    "people": 17,
    "finding": "Across several ways of summarizing the same trail run, OH1 mean absolute percentage error was 3.3% to 4.1%. Agreement based on concordance was more variable.",
    "locator": "Methods and Table 1",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "10-26773-smj-231004",
    "title": "Validity and Reliability of Wearable Devices during Self-Paced Walking, Jogging and Overground Skipping",
    "citation": "Navalta JW et al.",
    "year": 2023,
    "doi": "10.26773/smj.231004",
    "pmid": null,
    "url": "https://doi.org/10.26773/smj.231004",
    "setting": "Exercise",
    "devices": "Garmin Instinct, Polar Vantage M2, Polar Verity Sense, Polar OH1",
    "reference": "Polar H10",
    "people": 18,
    "finding": "During skipping, mean absolute percentage error was 21.7% on Garmin Instinct and 1.1% on Polar Verity Sense.",
    "locator": "Table 3",
    "evidence": "Published research",
    "resultsStudy": "gait"
  },
  {
    "id": "pmid-38083211",
    "title": "Towards Quantifying Stress in Patients with a History of Myocardial Infarction: Validating ECG-Derived Patch Features",
    "citation": "Nawar A et al.",
    "year": 2023,
    "doi": "10.1109/embc40787.2023.10340614",
    "pmid": "38083211",
    "url": "https://pubmed.ncbi.nlm.nih.gov/38083211/",
    "setting": "Clinical",
    "devices": "Experimental ECG patch",
    "reference": "BIOPAC ECG",
    "people": null,
    "finding": "During a public-speaking task, heart rate from the patch and BIOPAC ECG correlated above 0.90.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-37761281",
    "title": "Automatic Heart Rate Detection during Sleep Using Tracheal Audio Recordings from Wireless Acoustic Sensor",
    "citation": "Tomaszewska JZ et al.",
    "year": 2023,
    "doi": "10.3390/diagnostics13182914",
    "pmid": "37761281",
    "url": "https://pubmed.ncbi.nlm.nih.gov/37761281/",
    "setting": "Sleep and rest",
    "devices": "Wearable tracheal sound sensor",
    "reference": "Holter and polysomnography ECG",
    "people": 50,
    "finding": "The optical-free acoustic method was evaluated against polysomnography heart rate in 50 participants. Reported correlation was 0.82 at zero tolerance and 0.89 with a 3 bpm tolerance.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-38096010",
    "title": "Assessment of Heart Rate Monitoring During Exercise With Smart Wristbands and a Heart Rhythm Patch: Validation and Comparison Study",
    "citation": "Wang TL et al.",
    "year": 2023,
    "doi": "10.2196/52519",
    "pmid": "38096010",
    "url": "https://pubmed.ncbi.nlm.nih.gov/38096010/",
    "setting": "Exercise",
    "devices": "MobileAction Q-Band Q-69",
    "reference": "Wearable ECG patch",
    "people": null,
    "finding": "The correlation with the ECG patch was 0.63 for women and 0.81 for men overall. Agreement fell during running.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-37206121",
    "title": "Wearable cardiorespiratory monitoring with stretchable elastomer optical fiber",
    "citation": "Zha B et al.",
    "year": 2023,
    "doi": "10.1364/boe.490034",
    "pmid": "37206121",
    "url": "https://pubmed.ncbi.nlm.nih.gov/37206121/",
    "setting": "Sleep and rest",
    "devices": "Stretchable optical fiber belt",
    "reference": "ECG",
    "people": 10,
    "finding": "In prototype tests at several body positions, the largest reported heart-rate error was 3 bpm.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-36060539",
    "title": "Accurate detection of heart rate using in-ear photoplethysmography in a clinical setting",
    "citation": "Adams T et al.",
    "year": 2022,
    "doi": "10.3389/fdgth.2022.909519",
    "pmid": "36060539",
    "url": "https://pubmed.ncbi.nlm.nih.gov/36060539/",
    "setting": "Clinical",
    "devices": "Cosinuss in-ear PPG sensor",
    "reference": "Single-lead ECG",
    "people": 97,
    "finding": "After filtering by signal quality, the in-ear sensor averaged 0.78 bpm above ECG and had 2.57% mean absolute percentage error.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-36104356",
    "title": "Agreement between two photoplethysmography-based wearable devices for monitoring heart rate during different physical activity situations: a new analysis methodology.",
    "citation": "Alfonso C et al.",
    "year": 2022,
    "doi": "10.1038/s41598-022-18356-9",
    "pmid": "36104356",
    "url": "https://pubmed.ncbi.nlm.nih.gov/36104356/",
    "setting": "Exercise",
    "devices": "Apple Watch Series 6, Polar Vantage M2",
    "reference": "BIOPAC ECG",
    "people": 18,
    "finding": "Agreement was better lying down than walking. Differences from ECG were more pronounced in shorter averaging windows.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-35808157",
    "title": "Estimation of Heart Rate and Energy Expenditure Using a Smart Bracelet during Different Exercise Intensities: A Reliability and Validity Study",
    "citation": "Cai Y et al.",
    "year": 2022,
    "doi": "10.3390/s22134661",
    "pmid": "35808157",
    "url": "https://pubmed.ncbi.nlm.nih.gov/35808157/",
    "setting": "Exercise",
    "devices": "Lexin Mio smart bracelet",
    "reference": "Polar H10",
    "people": 65,
    "finding": "The authors found closer agreement for heart rate than for the calorie estimate across running tests at different intensities.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-35040799",
    "title": "Accuracy Assessment of Oura Ring Nocturnal Heart Rate and Heart Rate Variability in Comparison With Electrocardiography in Time and Frequency Domains: Comprehensive Analysis.",
    "citation": "Cao R et al.",
    "year": 2022,
    "doi": "10.2196/27487",
    "pmid": "35040799",
    "url": "https://pmc.ncbi.nlm.nih.gov/articles/PMC8808342/",
    "setting": "Sleep and rest",
    "devices": "Oura Ring",
    "reference": "Shimmer3 chest ECG",
    "people": 35,
    "finding": "Nightly and five-minute heart-rate estimates had low mean bias against ECG in this home study.",
    "locator": "Results",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-35808223",
    "title": "Accuracy and Precision of Wearable Devices for Real-Time Monitoring of Swimming Athletes.",
    "citation": "Cosoli G et al.",
    "year": 2022,
    "doi": "10.3390/s22134726",
    "pmid": "35808223",
    "url": "https://pmc.ncbi.nlm.nih.gov/articles/PMC9269005/",
    "setting": "Exercise",
    "devices": "Garmin Venu Sq, Polar Vantage V2",
    "reference": "Polar H10",
    "people": 10,
    "finding": "Watch and chest-strap readings were farther apart in water than on land for both devices. Vora reanalyzed the same cohort using the later public release.",
    "locator": "Figures 5–6 and public paired recordings",
    "evidence": "Published research",
    "resultsStudy": "swimmer"
  },
  {
    "id": "pmid-36329338",
    "title": "Evaluation of a Wearable in-Ear Sensor for Temperature and Heart Rate Monitoring: A Pilot Study.",
    "citation": "Ellebrecht DB et al.",
    "year": 2022,
    "doi": "10.1007/s10916-022-01872-6",
    "pmid": "36329338",
    "url": "https://pubmed.ncbi.nlm.nih.gov/36329338/",
    "setting": "Clinical",
    "devices": "Cosinuss One in-ear monitor",
    "reference": "Clinical ECG",
    "people": null,
    "finding": "During surgery, agreement limits were −4.81 to +4.27 bpm. About 84% of HR differences were within 2 bpm.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-36055073",
    "title": "Comparative study of a single lead ECG in a wearable device",
    "citation": "Funston R et al.",
    "year": 2022,
    "doi": "10.1016/j.jelectrocard.2022.08.004",
    "pmid": "36055073",
    "url": "https://pubmed.ncbi.nlm.nih.gov/36055073/",
    "setting": "Daily life",
    "devices": "HeartKey test watch, HeartKey Chest Module",
    "reference": "Bittium Faros 180 ECG",
    "people": null,
    "finding": "The watch algorithm gave mean absolute differences of 0.74 bpm while sitting, 1.21 bpm while walking and 0.80 bpm while standing. The watch dropped more beats than the chest module.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-36542432",
    "title": "Comparing a Fitbit Wearable to an Electrocardiogram Gold Standard as a Measure of Heart Rate Under Psychological Stress: A Validation Study.",
    "citation": "Gagnon J et al.",
    "year": 2022,
    "doi": "10.2196/37885",
    "pmid": "36542432",
    "url": "https://pubmed.ncbi.nlm.nih.gov/36542432/",
    "setting": "Sleep and rest",
    "devices": "Fitbit Versa 2",
    "reference": "BIOPAC ECG",
    "people": 34,
    "finding": "Agreement with ECG was poorer during higher-heart-rate phases of the laboratory psychological stress task.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-36048505",
    "title": "Measurement of Heart Rate Using the Withings ScanWatch Device During Free-living Activities: Validation Study.",
    "citation": "Giggins OM et al.",
    "year": 2022,
    "doi": "10.2196/34280",
    "pmid": "36048505",
    "url": "https://pubmed.ncbi.nlm.nih.gov/36048505/",
    "setting": "Daily life",
    "devices": "Withings ScanWatch",
    "reference": "Polar H10",
    "people": 7,
    "finding": "Across 12 hours of usual activities, errors were larger during ambulatory activities such as walking and gardening than during desk work or sitting.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-36501948",
    "title": "Validation of Wearable Device Consisting of a Smart Shirt with Built-In Bioelectrodes and a Wireless Transmitter for Heart Rate Monitoring in Light to Moderate Physical Work.",
    "citation": "Hashimoto Y et al.",
    "year": 2022,
    "doi": "10.3390/s22239241",
    "pmid": "36501948",
    "url": "https://pubmed.ncbi.nlm.nih.gov/36501948/",
    "setting": "Exercise",
    "devices": "Smart shirt with ECG bioelectrodes",
    "reference": "Holter ECG",
    "people": null,
    "finding": "During simulated work tasks including lifting, mean absolute percentage error was no greater than 0.92%.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-34994703",
    "title": "Continuous Monitoring of Vital Signs With Wearable Sensors During Daily Life Activities: Validation Study",
    "citation": "Haveman ME et al.",
    "year": 2022,
    "doi": "10.2196/30863",
    "pmid": "34994703",
    "url": "https://pubmed.ncbi.nlm.nih.gov/34994703/",
    "setting": "Daily life",
    "devices": "VitalPatch, Everion, Fitbit",
    "reference": "ECG reference",
    "people": null,
    "finding": "VitalPatch averaged 0.1 bpm above reference. The study reported larger underestimates for Everion and Fitbit, with wide agreement limits.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-35288797",
    "title": "Agreement of the Apple Watch® and Fitbit Charge® for recording step count and heart rate when exercising in water.",
    "citation": "Held NJ et al.",
    "year": 2022,
    "doi": "10.1007/s11517-022-02536-w",
    "pmid": "35288797",
    "url": "https://pubmed.ncbi.nlm.nih.gov/35288797/",
    "setting": "Exercise",
    "devices": "Apple Watch Series 4, Fitbit Charge 3",
    "reference": "Polar T31 chest strap",
    "people": 16,
    "finding": "During submerged treadmill walking and running, absolute error averaged 0.90 bpm for Apple Watch and 4.2 bpm for Fitbit.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-36583938",
    "title": "Accuracy and Systematic Biases of Heart Rate Measurements by Consumer-Grade Fitness Trackers in Postoperative Patients: Prospective Clinical Trial.",
    "citation": "Helmer P et al.",
    "year": 2022,
    "doi": "10.2196/42359",
    "pmid": "36583938",
    "url": "https://pubmed.ncbi.nlm.nih.gov/36583938/",
    "setting": "Clinical",
    "devices": "Apple Watch Series 7, Garmin Fenix 6 Pro, Withings ScanWatch, Fitbit Sense",
    "reference": "Clinical ECG",
    "people": 201,
    "finding": "All four devices had Pearson correlations of at least 0.95 during controlled heart-rate spot checks after surgery.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-35622397",
    "title": "Polar Vantage and Oura Physical Activity and Sleep Trackers: Validation and Comparison Study",
    "citation": "Henriksen A et al.",
    "year": 2022,
    "doi": "10.2196/27248",
    "pmid": "35622397",
    "url": "https://pubmed.ncbi.nlm.nih.gov/35622397/",
    "setting": "Daily life",
    "devices": "Oura Ring Gen 2",
    "reference": "Actiheart ECG",
    "people": 21,
    "finding": "Resting heart rate from Oura and Actiheart correlated at 0.90 over up to seven days of wear.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-36081752",
    "title": "Accuracy of wrist-worn wearable devices for determining exercise intensity.",
    "citation": "Ho WT et al.",
    "year": 2022,
    "doi": "10.1177/20552076221124393",
    "pmid": "36081752",
    "url": "https://pubmed.ncbi.nlm.nih.gov/36081752/",
    "setting": "Exercise",
    "devices": "Apple Watch Series 6, Garmin Forerunner 945",
    "reference": "ECG",
    "people": 30,
    "finding": "Across three specified exercise-intensity points, mean absolute error ranged from 1.16 to 1.48 bpm for Apple and 1.35 to 2.25 bpm for Garmin.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-35044306",
    "title": "Accuracy of Heart Rate Measurement by the Fitbit Charge 2 During Wheelchair Activities in People With Spinal Cord Injury: Instrument Validation Study.",
    "citation": "Hoevenaars D et al.",
    "year": 2022,
    "doi": "10.2196/27637",
    "pmid": "35044306",
    "url": "https://pubmed.ncbi.nlm.nih.gov/35044306/",
    "setting": "Clinical",
    "devices": "Fitbit Charge 2",
    "reference": "Polar H7",
    "people": 48,
    "finding": "Among participants with spinal cord injury, mean absolute percentage error was 6.5% at rest, 12.97% for wheelchair activities and 14.2% during strength exercise.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-36071003",
    "title": "Accuracy and Validity of Commercial Smart Bands for Heart Rate Measurements During Cardiopulmonary Exercise Test.",
    "citation": "Kim C et al.",
    "year": 2022,
    "doi": "10.5535/arm.22050",
    "pmid": "36071003",
    "url": "https://pubmed.ncbi.nlm.nih.gov/36071003/",
    "setting": "Clinical",
    "devices": "Samsung Galaxy Fit 2, Xiaomi Mi Band 5, Partron PWB-250, MobiCARE-MC100",
    "reference": "12-lead ECG and ECG patch",
    "people": 78,
    "finding": "All three bands had concordance above 0.90 below 100 bpm. Agreement tended to fall at higher heart rates.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-36016077",
    "title": "A Validation of Six Wearable Devices for Estimating Sleep, Heart Rate and Heart Rate Variability in Healthy Adults",
    "citation": "Miller DJ et al.",
    "year": 2022,
    "doi": "10.3390/s22166317",
    "pmid": "36016077",
    "url": "https://www.mdpi.com/1424-8220/22/16/6317",
    "setting": "Sleep and rest",
    "devices": "Apple Watch Series 6, Garmin Forerunner 245 Music, Polar Vantage V, Oura Ring Gen 2, WHOOP 3.0, Somfit",
    "reference": "Laboratory ECG",
    "people": 53,
    "finding": "Reported mean absolute differences in nighttime summary heart rate ranged from 0.7 to 5.4 bpm. Recording windows varied by device.",
    "locator": "Table 6 and Figure 2",
    "evidence": "Research group reports separate WHOOP support",
    "resultsStudy": "sleep"
  },
  {
    "id": "pmid-35230250",
    "title": "Heart Rate Measurement Accuracy of Fitbit Charge 4 and Samsung Galaxy Watch Active2: Device Evaluation Study.",
    "citation": "Nissen M et al.",
    "year": 2022,
    "doi": "10.2196/33635",
    "pmid": "35230250",
    "url": "https://formative.jmir.org/2022/3/e33635",
    "setting": "Exercise",
    "devices": "Fitbit Charge 4, Samsung Galaxy Watch Active2",
    "reference": "Holter ECG",
    "people": 23,
    "finding": "During squats, absolute error averaged 15.7 bpm for Fitbit and 6.1 bpm for Samsung. At seated rest it was 7.8 and 9.4 bpm, respectively.",
    "locator": "Table 4",
    "evidence": "Published research",
    "resultsStudy": "everyday-tasks"
  },
  {
    "id": "pmid-36252721",
    "title": "Validity of the Empatica E4 wristband to estimate resting-state heart rate variability in a lab-based context",
    "citation": "Stuyck H et al.",
    "year": 2022,
    "doi": "10.1016/j.ijpsycho.2022.10.003",
    "pmid": "36252721",
    "url": "https://pubmed.ncbi.nlm.nih.gov/36252721/",
    "setting": "Sleep and rest",
    "devices": "Empatica E4",
    "reference": "ECG",
    "people": null,
    "finding": "During seated rest, the researchers found close agreement for average pulse rate with windows as short as 10 seconds.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-36803578",
    "title": "Accuracy of the Apple Watch Series 6 and the Whoop Band 3.0 for assessing heart rate during resistance exercises.",
    "citation": "Støve MP et al.",
    "year": 2022,
    "doi": "10.1080/02640414.2023.2180160",
    "pmid": "36803578",
    "url": "https://pubmed.ncbi.nlm.nih.gov/36803578/",
    "setting": "Exercise",
    "devices": "Apple Watch Series 6, WHOOP 3.0",
    "reference": "Polar H10",
    "people": 29,
    "finding": "Apple Watch correlations exceeded 0.832 for squats, deadlifts and seated rows. Agreement was weaker in the curl-to-press and burpee exercises.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-35434406",
    "title": "Accuracy of Heart Rate and Respiratory Rate Measurements Using Two Types of Wearable Devices",
    "citation": "Takahashi Y et al.",
    "year": 2022,
    "doi": "10.2490/prm.20220016",
    "pmid": "35434406",
    "url": "https://pubmed.ncbi.nlm.nih.gov/35434406/",
    "setting": "Exercise",
    "devices": "Silmee W22",
    "reference": "12-lead ECG",
    "people": 10,
    "finding": "The regression standard error for heart rate was below 10 bpm at rest and at constant workload, and above 10 bpm as cycling workload increased.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-32449291",
    "title": "Accuracy of Wearable Devices for Measuring Heart Rate During Conventional and Nordic Walking.",
    "citation": "Baek S et al.",
    "year": 2021,
    "doi": "10.1002/pmrj.12424",
    "pmid": "32449291",
    "url": "https://pubmed.ncbi.nlm.nih.gov/32449291/",
    "setting": "Exercise",
    "devices": "Fitbit Charge 2, Polar H7",
    "reference": "12-lead ECG",
    "people": 15,
    "finding": "Fitbit's mean absolute difference increased from 3.68 bpm during conventional walking to 6.60 bpm during Nordic walking.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-34065516",
    "title": "Wrist-Based Photoplethysmography Assessment of Heart Rate and Heart Rate Variability: Validation of WHOOP.",
    "citation": "Bellenger CR et al.",
    "year": 2021,
    "doi": "10.3390/s21103571",
    "pmid": "34065516",
    "url": "https://pubmed.ncbi.nlm.nih.gov/34065516/",
    "setting": "Sleep and rest",
    "devices": "WHOOP strap",
    "reference": "ECG",
    "people": null,
    "finding": "Relative heart-rate bias was at most 0.39% across the signal filters examined during sleep.",
    "locator": "Abstract",
    "evidence": "Author disclosed WHOOP affiliation",
    "resultsStudy": null
  },
  {
    "id": "pmid-33837981",
    "title": "Heart rate detection by Fitbit ChargeHR ™ : A validation study versus portable polysomnography.",
    "citation": "Benedetti D et al.",
    "year": 2021,
    "doi": "10.1111/jsr.13346",
    "pmid": "33837981",
    "url": "https://pubmed.ncbi.nlm.nih.gov/33837981/",
    "setting": "Sleep and rest",
    "devices": "Fitbit Charge HR",
    "reference": "Portable polysomnography ECG",
    "people": 25,
    "finding": "Mean difference over at least 12 hours was −0.66 bpm. Correlation was 0.374 above 100 bpm and 0.84 below 100 bpm.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-35009723",
    "title": "Heart Rate and Distance Measurement of Two Multisport Activity Trackers and a Cellphone App in Different Sports: A Cross-Sectional Validation and Comparison Field Study.",
    "citation": "Budig M et al.",
    "year": 2021,
    "doi": "10.3390/s22010180",
    "pmid": "35009723",
    "url": "https://www.mdpi.com/1424-8220/22/1/180",
    "setting": "Exercise",
    "devices": "Garmin Forerunner 945, Polar Ignite",
    "reference": "Polar H10",
    "people": 36,
    "finding": "Mean absolute error was 3.29 and 3.23 bpm, respectively, in the pooled non-swimming measurements. At 1,000 m swimming, it was 42.72 and 39.44 bpm.",
    "locator": "Table 1",
    "evidence": "Published research",
    "resultsStudy": "multisport"
  },
  {
    "id": "pmid-34892707",
    "title": "Accuracy of Wrist-Worn Photoplethysmography Devices at Measuring Heart Rate in the Laboratory and During Free-Living Activities",
    "citation": "Giggins OM et al.",
    "year": 2021,
    "doi": "10.1109/embc46164.2021.9629522",
    "pmid": "34892707",
    "url": "https://pubmed.ncbi.nlm.nih.gov/34892707/",
    "setting": "Exercise",
    "devices": "Apple Watch Series 5, Empatica E4",
    "reference": "Polar H10",
    "people": 10,
    "finding": "The lab test compared both watches on a treadmill. In the separate one-person daytime test, Empatica tended to read high in normal activities and low in more strenuous activities.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-34340217",
    "title": "Validation of ambulatory monitoring devices to measure energy expenditure and heart rate in a military setting",
    "citation": "Gilgen-Ammann R et al.",
    "year": 2021,
    "doi": "10.1088/1361-6579/ac19f9",
    "pmid": "34340217",
    "url": "https://pubmed.ncbi.nlm.nih.gov/34340217/",
    "setting": "Exercise",
    "devices": "Actiheart, Everion, Garmin fēnix 3, PADIS 2.0",
    "reference": "Hidalgo Equivital EQ02 ECG",
    "people": 33,
    "finding": "Mean signed heart-rate errors ranged from −0.1 bpm for PADIS to +0.8 bpm for Actiheart in a military activity protocol.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-34365430",
    "title": "COMPARISON OF WEARABLES FOR SELF-MONITORING OF HEART RATE IN CORONARY REHABILITATION PATIENTS",
    "citation": "Heyken M et al.",
    "year": 2021,
    "doi": null,
    "pmid": "34365430",
    "url": "https://pubmed.ncbi.nlm.nih.gov/34365430/",
    "setting": "Clinical",
    "devices": "Wearables from Apple, Mio, Garmin and Withings",
    "reference": "ECG telemetry",
    "people": 35,
    "finding": "Apple, Mio and Garmin tracked ECG more closely than the tested Withings model during constant-load cardiac rehabilitation cycling.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-33555260",
    "title": "Heart Rate Measurements in Patients with Obstructive Sleep Apnea and Atrial Fibrillation: Prospective Pilot Study Assessing Apple Watch's Agreement With Telemetry Data.",
    "citation": "Huynh P et al.",
    "year": 2021,
    "doi": "10.2196/18050",
    "pmid": "33555260",
    "url": "https://pubmed.ncbi.nlm.nih.gov/33555260/",
    "setting": "Clinical",
    "devices": "Apple Watch",
    "reference": "Hospital ECG telemetry",
    "people": 20,
    "finding": "The concordance coefficient was 0.88 in a one-minute test before procedures in patients with atrial fibrillation and sleep apnea. The spread of differences increased as heart rate rose.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-35009603",
    "title": "Wristbands in Home-Based Rehabilitation-Validation of Heart Rate Measurement.",
    "citation": "Jachymek M et al.",
    "year": 2021,
    "doi": "10.3390/s22010060",
    "pmid": "35009603",
    "url": "https://pubmed.ncbi.nlm.nih.gov/35009603/",
    "setting": "Exercise",
    "devices": "Fitbit Charge 4, Xiaomi Mi Band 5",
    "reference": "ECG",
    "people": 31,
    "finding": "Mean absolute percentage error was 10.19% for Fitbit and 6.89% for Xiaomi in a graded treadmill stress test.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-32734757",
    "title": "The accuracy of fitness watches for the measurement of heart rate and energy expenditure during moderate intensity exercise.",
    "citation": "Jagim AR et al.",
    "year": 2021,
    "doi": "10.23736/s0022-4707.20.11151-4",
    "pmid": "32734757",
    "url": "https://pubmed.ncbi.nlm.nih.gov/32734757/",
    "setting": "Exercise",
    "devices": "Fitbit Versa, Polar Ignite, Polar Team Pro",
    "reference": "ECG",
    "people": 20,
    "finding": "Mean absolute percentage error in the incremental exercise protocol was 11.6% for Fitbit Versa, 11.0% for Polar Ignite and 6.3% for the Polar chest strap.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-33519074",
    "title": "Accuracy of wrist-worn heart rate monitors during physical therapy sessions among hemiparetic inpatients with stroke.",
    "citation": "Kobayashi M et al.",
    "year": 2021,
    "doi": "10.1589/jpts.33.45",
    "pmid": "33519074",
    "url": "https://pubmed.ncbi.nlm.nih.gov/33519074/",
    "setting": "Clinical",
    "devices": "Polar A370",
    "reference": "ECG chest monitor",
    "people": 30,
    "finding": "During stroke rehabilitation, mean absolute percentage error was 5.9% on the affected side and 6.7% on the other.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-34286857",
    "title": "Cross-instrument feasibility, validity, and reproducibility of wireless heart rate monitors: Novel opportunities for extended daily life monitoring",
    "citation": "Kunkels YK et al.",
    "year": 2021,
    "doi": "10.1111/psyp.13898",
    "pmid": "34286857",
    "url": "https://pubmed.ncbi.nlm.nih.gov/34286857/",
    "setting": "Sleep and rest",
    "devices": "Ithlete, Cortrium C3",
    "reference": "VU-AMS ECG",
    "people": null,
    "finding": "The wireless ECG and finger optical sensor both tracked the reference in low-motion laboratory tests.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-34734834",
    "title": "Validation of Heart Rate Extracted From Wrist-Based Photoplethysmography in the Perioperative Setting: Prospective Observational Study.",
    "citation": "Mestrom E et al.",
    "year": 2021,
    "doi": "10.2196/27765",
    "pmid": "34734834",
    "url": "https://pubmed.ncbi.nlm.nih.gov/34734834/",
    "setting": "Clinical",
    "devices": "Wrist optical heart-rate monitor",
    "reference": "5-lead ECG",
    "people": 99,
    "finding": "During surgery, mean bias was −0.14 bpm, with agreement limits −3.08 to +2.79 bpm.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-33764310",
    "title": "Measurement of Heart Rate Using the Polar OH1 and Fitbit Charge 3 Wearable Devices in Healthy Adults During Light, Moderate, Vigorous, and Sprint-Based Exercise: Validation Study.",
    "citation": "Muggeridge DJ et al.",
    "year": 2021,
    "doi": "10.2196/25313",
    "pmid": "33764310",
    "url": "https://pubmed.ncbi.nlm.nih.gov/33764310/",
    "setting": "Exercise",
    "devices": "Polar OH1, Fitbit Charge 3",
    "reference": "Polar H10",
    "people": 20,
    "finding": "Across treadmill and cycling trials including sprints, bias was −1 bpm for Polar OH1 and −7 bpm for Fitbit. Fitbit's reported agreement limits were −46 to +33 bpm.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-34960501",
    "title": "Comparison of Heart Rate Monitoring Accuracy between Chest Strap and Vest during Physical Training and Implications on Training Decisions.",
    "citation": "Parak J et al.",
    "year": 2021,
    "doi": "10.3390/s21248411",
    "pmid": "34960501",
    "url": "https://pubmed.ncbi.nlm.nih.gov/34960501/",
    "setting": "Exercise",
    "devices": "Chest strap and ECG sports vest",
    "reference": "3-lead Holter ECG",
    "people": 25,
    "finding": "With the same sensor mounted in each, mean absolute percentage error was 0.76% in the strap and 3.32% in the vest.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-34398076",
    "title": "Examining the Accuracy of the Polar A360 Monitor",
    "citation": "Rider BC et al.",
    "year": 2021,
    "doi": "10.1519/jsc.0000000000003136",
    "pmid": "34398076",
    "url": "https://pubmed.ncbi.nlm.nih.gov/34398076/",
    "setting": "Exercise",
    "devices": "Polar A360",
    "reference": "Polar RS400 chest strap",
    "people": 30,
    "finding": "Across resting, treadmill and recovery readings, the intraclass correlation with the chest strap was 0.98.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "10-1177-1754337120976659",
    "title": "Comparison between photoplethysmographic heart rate monitor from Polar Vantage M and Polar V800 with H10 chest strap while running on a treadmill",
    "citation": "Ruiz-Malagón EJ et al.",
    "year": 2021,
    "doi": "10.1177/1754337120976659",
    "pmid": null,
    "url": "https://doi.org/10.1177/1754337120976659",
    "setting": "Exercise",
    "devices": "Polar Vantage M",
    "reference": "Polar H10 recorded on Polar V800",
    "people": 37,
    "finding": "The treadmill test reported +0.26 bpm of bias over 600 seconds and −5.13 bpm over the ten-second comparison.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-33614295",
    "title": "Validity of the Polar Vantage M watch when measuring heart rate at different exercise intensities.",
    "citation": "Shumate T et al.",
    "year": 2021,
    "doi": "10.7717/peerj.10893",
    "pmid": "33614295",
    "url": "https://pubmed.ncbi.nlm.nih.gov/33614295/",
    "setting": "Exercise",
    "devices": "Polar Vantage M",
    "reference": "5-lead ECG",
    "people": 28,
    "finding": "Overall R² was 0.87, with poorer validity in the higher treadmill stages.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-33433391",
    "title": "Wrist-Worn Activity Trackers in Laboratory and Free-Living Settings for Patients With Chronic Pain: Criterion Validity Study",
    "citation": "Sjöberg V et al.",
    "year": 2021,
    "doi": "10.2196/24806",
    "pmid": "33433391",
    "url": "https://pubmed.ncbi.nlm.nih.gov/33433391/",
    "setting": "Clinical",
    "devices": "Fitbit Versa",
    "reference": "Jaeger Oxycon Pro ECG",
    "people": 42,
    "finding": "During treadmill walking at three speeds, heart-rate agreement ranged from poor to fair.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-33733234",
    "title": "Assessing the Accuracy of Popular Commercial Technologies That Measure Resting Heart Rate and Heart Rate Variability",
    "citation": "Stone JD et al.",
    "year": 2021,
    "doi": "10.3389/fspor.2021.585870",
    "pmid": "33733234",
    "url": "https://doi.org/10.3389/fspor.2021.585870",
    "setting": "Sleep and rest",
    "devices": "Firstbeat chest sensor, Polar H10 and optical and app-based tools",
    "reference": "Multi-lead ECG",
    "people": 5,
    "finding": "The Firstbeat chest sensor had no reported percentage error for the resting averages in this five-person test. Other devices and app configurations had larger errors.",
    "locator": "Table 2",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-34609317",
    "title": "Validation of Fitbit Charge 2 Sleep and Heart Rate Estimates Against Polysomnographic Measures in Shift Workers: Naturalistic Study.",
    "citation": "Stucky B et al.",
    "year": 2021,
    "doi": "10.2196/26476",
    "pmid": "34609317",
    "url": "https://pubmed.ncbi.nlm.nih.gov/34609317/",
    "setting": "Sleep and rest",
    "devices": "Fitbit Charge 2",
    "reference": "Portable polysomnography ECG",
    "people": 59,
    "finding": "In shift workers, Fitbit underestimated nighttime heart rate by 0.9 bpm on average. Underestimation was greater during wakefulness than in deeper sleep.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-31787389",
    "title": "Accuracy of wrist-worn heart rate monitors for rate control assessment in atrial fibrillation.",
    "citation": "Al-Kaisey AM et al.",
    "year": 2020,
    "doi": "10.1016/j.ijcard.2019.11.120",
    "pmid": "31787389",
    "url": "https://pubmed.ncbi.nlm.nih.gov/31787389/",
    "setting": "Clinical",
    "devices": "Apple Watch Series 3, Fitbit Charge HR",
    "reference": "24-hour Holter ECG",
    "people": 32,
    "finding": "Among participants with atrial fibrillation, the reported bias was −28 bpm at reference rates of 100 to 120 bpm, versus −6 bpm at 80 to 100 bpm.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-32343255",
    "title": "Accuracy of Optical Heart Rate Sensing Technology in Wearable Fitness Trackers for Young and Older Adults: Validation and Comparison Study.",
    "citation": "Chow HW et al.",
    "year": 2020,
    "doi": "10.2196/14707",
    "pmid": "32343255",
    "url": "https://pubmed.ncbi.nlm.nih.gov/32343255/",
    "setting": "Exercise",
    "devices": "Garmin Vivosmart HR+, Xiaomi Mi Band 2",
    "reference": "Polar H7",
    "people": 40,
    "finding": "Both trackers had overall mean absolute percentage error below 10% across moderate exercise and sedentary activities. Some individual readings were much farther off.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-32374274",
    "title": "Wrist-Worn Wearables for Monitoring Heart Rate and Energy Expenditure While Sitting or Performing Light-to-Vigorous Physical Activity: Validation Study.",
    "citation": "Düking P et al.",
    "year": 2020,
    "doi": "10.2196/16716",
    "pmid": "32374274",
    "url": "https://pubmed.ncbi.nlm.nih.gov/32374274/",
    "setting": "Exercise",
    "devices": "Apple Watch Series 4, Polar Vantage V, Garmin Fenix 5, Fitbit Versa",
    "reference": "Polar H7",
    "people": 25,
    "finding": "The standardized typical error across activities was 0.09 to 0.62 for Apple Watch and 0.47 to 1.94 for Fitbit Versa.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-32848879",
    "title": "Ecological Validation and Reliability of Hexoskin Wearable Body Metrics Tool in Measuring Pre-exercise and Peak Heart Rate During Shuttle Run Test in Professional Handball Players",
    "citation": "Haddad M et al.",
    "year": 2020,
    "doi": "10.3389/fphys.2020.00957",
    "pmid": "32848879",
    "url": "https://pubmed.ncbi.nlm.nih.gov/32848879/",
    "setting": "Exercise",
    "devices": "Hexoskin smart shirt",
    "reference": "ECG chest monitor",
    "people": 9,
    "finding": "During a shuttle run, vigorous movement made the shirt readings unusable for four of nine professional handball players.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-32012044",
    "title": "Use of a Smart Watch for Early Detection of Paroxysmal Atrial Fibrillation: Validation Study",
    "citation": "Inui T et al.",
    "year": 2020,
    "doi": "10.2196/14857",
    "pmid": "32012044",
    "url": "https://pubmed.ncbi.nlm.nih.gov/32012044/",
    "setting": "Clinical",
    "devices": "Apple Watch Series 3, Fitbit Charge HR",
    "reference": "Telemetry ECG",
    "people": 40,
    "finding": "During postoperative atrial fibrillation, wearable pulse-rate trends reached at least moderate correlation with ECG in 12 of 16 Apple Watch workout-mode episodes and 6 of 20 Fitbit episodes.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-32866216",
    "title": "Concurrent heart rate validity of wearable technology devices during trail running.",
    "citation": "Navalta JW et al.",
    "year": 2020,
    "doi": "10.1371/journal.pone.0238569",
    "pmid": "32866216",
    "url": "https://journals.plos.org/plosone/article?id=10.1371/journal.pone.0238569",
    "setting": "Exercise",
    "devices": "Garmin Fenix 5, Jabra Elite Sport, Motiv Ring, Scosche Rhythm+, Suunto Spartan Sport with chest strap",
    "reference": "Polar H7",
    "people": 21,
    "finding": "Whole-trail mean absolute error was 7.3 bpm for Scosche Rhythm+ and 2.9 bpm for the Suunto chest strap setup.",
    "locator": "Tables 1–3",
    "evidence": "Published research",
    "resultsStudy": "trail"
  },
  {
    "id": "pmid-32899540",
    "title": "A Study on the Effect of Contact Pressure during Physical Activity on Photoplethysmographic Heart Rate Measurements",
    "citation": "Scardulla F et al.",
    "year": 2020,
    "doi": "10.3390/s20185052",
    "pmid": "32899540",
    "url": "https://pubmed.ncbi.nlm.nih.gov/32899540/",
    "setting": "Exercise",
    "devices": "Pressure-controlled wrist PPG prototype",
    "reference": "ECG chest strap",
    "people": 17,
    "finding": "At 54 mmHg sensor contact pressure, mean absolute percentage error ranged from 2.4% to 3.8% across activity rates.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-32965570",
    "title": "Validity of the Empatica E4 Wristband to Measure Heart Rate Variability (HRV) Parameters: a Comparison to Electrocardiography (ECG)",
    "citation": "Schuurmans AAT et al.",
    "year": 2020,
    "doi": "10.1007/s10916-020-01648-w",
    "pmid": "32965570",
    "url": "https://pubmed.ncbi.nlm.nih.gov/32965570/",
    "setting": "Sleep and rest",
    "devices": "Empatica E4",
    "reference": "ECG",
    "people": null,
    "finding": "Under resting, low-motion conditions, heart rate was the one tested measure for which the two monitors showed no significant average difference.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-32354450",
    "title": "Common wearable devices demonstrate variable accuracy in measuring heart rate during supraventricular tachycardia.",
    "citation": "Sequeira N et al.",
    "year": 2020,
    "doi": "10.1016/j.hrthm.2020.02.018",
    "pmid": "32354450",
    "url": "https://pubmed.ncbi.nlm.nih.gov/32354450/",
    "setting": "Clinical",
    "devices": "Apple Watch, Fitbit Charge HR, Garmin Vivosmart HR, Polar A360",
    "reference": "12-lead ECG",
    "people": 52,
    "finding": "All four wearables performed poorly for short episodes of induced supraventricular tachycardia. Accuracy improved for some devices with longer episodes.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-32128290",
    "title": "Accuracy of the Apple Watch 4 to Measure Heart Rate in Patients With Atrial Fibrillation",
    "citation": "Seshadri DR et al.",
    "year": 2020,
    "doi": "10.1109/jtehm.2019.2950397",
    "pmid": "32128290",
    "url": "https://pubmed.ncbi.nlm.nih.gov/32128290/",
    "setting": "Clinical",
    "devices": "Apple Watch Series 4",
    "reference": "Telemetry ECG",
    "people": 50,
    "finding": "The overall correlation of Apple Watch readings with telemetry was 0.70 in patients with atrial fibrillation.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-32404012",
    "title": "Measurement latency significantly contributes to reduced heart rate measurement accuracy in wearable devices.",
    "citation": "Støve MP et al.",
    "year": 2020,
    "doi": "10.1080/03091902.2020.1753836",
    "pmid": "32404012",
    "url": "https://pubmed.ncbi.nlm.nih.gov/32404012/",
    "setting": "Exercise",
    "devices": "Apple Watch Series 2, Garmin Forerunner 235",
    "reference": "Polar H10",
    "people": null,
    "finding": "The authors attributed 15% of the explained discrepancy to measurement latency for Garmin and 2% for Apple in their movement and exercise protocol.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-32663136",
    "title": "Using Smart Bracelets to Assess Heart Rate Among Students During Physical Education Lessons: Feasibility, Reliability, and Validity Study",
    "citation": "Sun J et al.",
    "year": 2020,
    "doi": "10.2196/17699",
    "pmid": "32663136",
    "url": "https://pubmed.ncbi.nlm.nih.gov/32663136/",
    "setting": "Exercise",
    "devices": "Fizzo smart bracelet",
    "reference": "Polar Team2 Pro chest strap",
    "people": null,
    "finding": "During physical education classes, mean bias was −2.60 bpm, with agreement limits from −38.89 to +33.69 bpm.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-30899354",
    "title": "Validity and Wearability of Consumer-based Fitness Trackers in Free-living Children.",
    "citation": "Brazendale K et al.",
    "year": 2019,
    "doi": "10.70252/bbtu4889",
    "pmid": "30899354",
    "url": "https://pubmed.ncbi.nlm.nih.gov/30899354/",
    "setting": "Daily life",
    "devices": "Fitbit Charge HR",
    "reference": "Polar ECG chest strap",
    "people": 19,
    "finding": "Mean absolute percentage difference was 6.9% during two hours of usual camp activities in children.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-30899350",
    "title": "Evaluation of Earbud and Wristwatch Heart Rate Monitors during Aerobic and Resistance Training.",
    "citation": "Bunn J et al.",
    "year": 2019,
    "doi": "10.70252/loox1045",
    "pmid": "30899350",
    "url": "https://pubmed.ncbi.nlm.nih.gov/30899350/",
    "setting": "Exercise",
    "devices": "Jabra earbuds, Mio Alpha",
    "reference": "Polar ECG chest strap",
    "people": 22,
    "finding": "Across treadmill, interval and outdoor exercise, mean absolute percentage error averaged 3.14% for the earbuds and 5.73% for the watch.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-31275816",
    "title": "Accuracy of wearable heart rate monitors in cardiac rehabilitation.",
    "citation": "Etiwy M et al.",
    "year": 2019,
    "doi": "10.21037/cdt.2019.04.08",
    "pmid": "31275816",
    "url": "https://pubmed.ncbi.nlm.nih.gov/31275816/",
    "setting": "Clinical",
    "devices": "Apple Watch, Fitbit Blaze, Garmin Forerunner 235, TomTom Spark Cardio, Polar H7",
    "reference": "ECG",
    "people": 80,
    "finding": "During cardiac rehabilitation treadmill exercise, the Apple Watch read 1.3 bpm high and the Fitbit Blaze read 0.5 bpm low on average against ECG. The Apple Watch generation was unspecified.",
    "locator": "Table 2 and analysis plan",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-30888332",
    "title": "Accuracy of Apple Watch Measurements for Heart Rate and Energy Expenditure in Patients With Cardiovascular Disease: Cross-Sectional Study",
    "citation": "Falter M et al.",
    "year": 2019,
    "doi": "10.2196/11889",
    "pmid": "30888332",
    "url": "https://pubmed.ncbi.nlm.nih.gov/30888332/",
    "setting": "Clinical",
    "devices": "Apple Watch",
    "reference": "12-lead ECG",
    "people": 40,
    "finding": "During graded cycling in people with cardiovascular disease, the smallest detectable difference ranged from 12.0 to 16.2 bpm across three test phases.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-30024125",
    "title": "The use of a smart-textile garment during high-intensity functional training: a pilot study",
    "citation": "Feito Y et al.",
    "year": 2019,
    "doi": "10.23736/s0022-4707.18.08689-9",
    "pmid": "30024125",
    "url": "https://pubmed.ncbi.nlm.nih.gov/30024125/",
    "setting": "Exercise",
    "devices": "Hexoskin smart garment",
    "reference": "12-lead ECG",
    "people": 10,
    "finding": "During treadmill activity, the heart-rate difference was under 10% during exercise and 4% during cooldown.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-31687372",
    "title": "Variable agreement between wearable heart rate monitors during exercise in cystic fibrosis.",
    "citation": "Gaynor M et al.",
    "year": 2019,
    "doi": "10.1183/23120541.00006-2019",
    "pmid": "31687372",
    "url": "https://pubmed.ncbi.nlm.nih.gov/31687372/",
    "setting": "Clinical",
    "devices": "Fitbit Charge HR, Polar H7, Masimo Rad-5v",
    "reference": "3-lead ECG",
    "people": null,
    "finding": "Fitbit Charge HR bias was 9 bpm during continuous cycling and 5 bpm during interval cycling in adults with cystic fibrosis.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-30990098",
    "title": "Accuracy of PurePulse photoplethysmography technology of Fitbit Charge 2 for assessment of heart rate during sleep.",
    "citation": "Haghayegh S et al.",
    "year": 2019,
    "doi": "10.1080/07420528.2019.1596947",
    "pmid": "30990098",
    "url": "https://pubmed.ncbi.nlm.nih.gov/30990098/",
    "setting": "Sleep and rest",
    "devices": "Fitbit Charge 2",
    "reference": "3-lead ECG",
    "people": 35,
    "finding": "Mean overnight heart rate differed by 0.09 bpm on average. This is a nightly mean comparison.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-31189190",
    "title": "Validation of a Photoplethysmographic Heart Rate Monitor: Polar OH1.",
    "citation": "Hermand E et al.",
    "year": 2019,
    "doi": "10.1055/a-0875-4033",
    "pmid": "31189190",
    "url": "https://pubmed.ncbi.nlm.nih.gov/31189190/",
    "setting": "Exercise",
    "devices": "Polar OH1",
    "reference": "Polar H7",
    "people": 70,
    "finding": "The width of the reported agreement limits ranged from 7 to 20 bpm across seven sports.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-31120968",
    "title": "Validation of Polar OH1 optical heart rate sensor for moderate and high intensity physical activities.",
    "citation": "Hettiarachchi IT et al.",
    "year": 2019,
    "doi": "10.1371/journal.pone.0217288",
    "pmid": "31120968",
    "url": "https://pubmed.ncbi.nlm.nih.gov/31120968/",
    "setting": "Exercise",
    "devices": "Polar OH1",
    "reference": "ECG",
    "people": 24,
    "finding": "Mean bias across cycling and treadmill conditions was between +0.27 and +0.33 bpm across the forearm, upper arm and temple placements.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-30808083",
    "title": "Assessing Accuracy of Wrist-Worn Wearable Devices in Measurement of Paroxysmal Supraventricular Tachycardia Heart Rate.",
    "citation": "Hwang J et al.",
    "year": 2019,
    "doi": "10.4070/kcj.2018.0323",
    "pmid": "30808083",
    "url": "https://pubmed.ncbi.nlm.nih.gov/30808083/",
    "setting": "Clinical",
    "devices": "Apple Watch Series 2, Samsung Gear S3, Fitbit Charge 2",
    "reference": "ECG",
    "people": 51,
    "finding": "During induced supraventricular tachycardia, 100% of Apple, 90% of Samsung and 87% of Fitbit measurements were within 10 bpm of ECG.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-31332802",
    "title": "Stressing the accuracy: Wrist-worn wearable sensor validation over different conditions",
    "citation": "Menghini L et al.",
    "year": 2019,
    "doi": "10.1111/psyp.13441",
    "pmid": "31332802",
    "url": "https://pubmed.ncbi.nlm.nih.gov/31332802/",
    "setting": "Sleep and rest",
    "devices": "Empatica E4",
    "reference": "Laboratory ECG",
    "people": 40,
    "finding": "The wristband’s mean heart rate agreed better with the ECG than its heart-rate variability estimates. The protocol included stress and motion tasks.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-31579026",
    "title": "Heart Rate Measures From Wrist-Worn Activity Trackers in a Laboratory and Free-Living Setting: Validation Study.",
    "citation": "Müller AM et al.",
    "year": 2019,
    "doi": "10.2196/14120",
    "pmid": "31579026",
    "url": "https://pubmed.ncbi.nlm.nih.gov/31579026/",
    "setting": "Daily life",
    "devices": "Tempo HR, Polar A370",
    "reference": "Polar H10",
    "people": null,
    "finding": "Tempo HR mean absolute percentage error was 13.00% during lab cycling and 10.20% in daily life.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-30855232",
    "title": "Accuracy of Consumer Wearable Heart Rate Measurement During an Ecologically Valid 24-Hour Period: Intraindividual Validation Study.",
    "citation": "Nelson BW et al.",
    "year": 2019,
    "doi": "10.2196/10828",
    "pmid": "30855232",
    "url": "https://pubmed.ncbi.nlm.nih.gov/30855232/",
    "setting": "Daily life",
    "devices": "Apple Watch Series 3, Fitbit Charge 2",
    "reference": "Ambulatory ECG",
    "people": 1,
    "finding": "Over 24 hours in one person, mean absolute percentage error was 5.86% for Apple Watch and 5.96% for Fitbit.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-31555543",
    "title": "Accuracy of commercially available heart rate monitors in athletes: a prospective study.",
    "citation": "Pasadyn SR et al.",
    "year": 2019,
    "doi": "10.21037/cdt.2019.06.05",
    "pmid": "31555543",
    "url": "https://pubmed.ncbi.nlm.nih.gov/31555543/",
    "setting": "Exercise",
    "devices": "Apple Watch Series 3, Fitbit Ionic, Garmin Vivosmart HR, TomTom Spark 3, Polar H7",
    "reference": "3-lead ECG",
    "people": 50,
    "finding": "Treadmill concordance was 0.98 for the Polar H7 and 0.96 for Apple Watch. The other three watches each had concordance of 0.89.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-31438600",
    "title": "In-Ear Pulse Rate Measurement: A Valid Alternative to Heart Rate Derived from Electrocardiography?",
    "citation": "Passler S et al.",
    "year": 2019,
    "doi": "10.3390/s19173641",
    "pmid": "31438600",
    "url": "https://pubmed.ncbi.nlm.nih.gov/31438600/",
    "setting": "Exercise",
    "devices": "Dash Pro, Cosinuss One",
    "reference": "Firstbeat Bodyguard2 ECG",
    "people": 20,
    "finding": "Both in-ear devices had mean absolute percentage error of 5% or less on a bike ergometer and tended to underestimate heart rate.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-31119387",
    "title": "Pilot Study Assessing the Influence of Skin Type on the Heart Rate Measurements Obtained by Photoplethysmography with the Apple Watch.",
    "citation": "Sañudo B et al.",
    "year": 2019,
    "doi": "10.1007/s10916-019-1325-2",
    "pmid": "31119387",
    "url": "https://pubmed.ncbi.nlm.nih.gov/31119387/",
    "setting": "Exercise",
    "devices": "Apple Watch",
    "reference": "Polar ECG heart-rate monitor",
    "people": 45,
    "finding": "In graded cycling, statistically detectable skin-type differences corresponded to less than 2% relative difference from the reference in the tested groups.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-30946696",
    "title": "Laboratory Validation of Hexoskin Biometric Shirt at Rest, Submaximal Exercise, and Maximal Exercise While Riding a Stationary Bicycle",
    "citation": "Smith CM et al.",
    "year": 2019,
    "doi": "10.1097/jom.0000000000001537",
    "pmid": "30946696",
    "url": "https://pubmed.ncbi.nlm.nih.gov/30946696/",
    "setting": "Exercise",
    "devices": "Hexoskin smart shirt",
    "reference": "12-lead ECG",
    "people": 17,
    "finding": "During stationary cycling, heart-rate discrepancies were below 10% across rest, submaximal and maximal exercise.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-31112585",
    "title": "Accuracy of consumer-level and research-grade activity trackers in ambulatory settings in older adults",
    "citation": "Tedesco S et al.",
    "year": 2019,
    "doi": "10.1371/journal.pone.0216891",
    "pmid": "31112585",
    "url": "https://pubmed.ncbi.nlm.nih.gov/31112585/",
    "setting": "Exercise",
    "devices": "Consumer wrist trackers",
    "reference": "ECG chest strap",
    "people": null,
    "finding": "Average error was between about −3.6 and +4.2 bpm, but the authors saw individual readings that were as much as 30 bpm too low.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-30657025",
    "title": "Heart rate measures from the Apple Watch, Fitbit Charge HR 2, and electrocardiogram across different exercise intensities.",
    "citation": "Thomson EA et al.",
    "year": 2019,
    "doi": "10.1080/02640414.2018.1560644",
    "pmid": "30657025",
    "url": "https://pubmed.ncbi.nlm.nih.gov/30657025/",
    "setting": "Exercise",
    "devices": "Apple Watch, Fitbit Charge 2",
    "reference": "ECG",
    "people": 30,
    "finding": "Relative errors across treadmill intensities ranged from 2.4% to 5.1% for Apple Watch and 3.9% to 13.5% for Fitbit.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-29090987",
    "title": "The validity and inter-device variability of the Apple Watch™ for measuring maximal heart rate.",
    "citation": "Abt G et al.",
    "year": 2018,
    "doi": "10.1080/02640414.2017.1397282",
    "pmid": "29090987",
    "url": "https://pubmed.ncbi.nlm.nih.gov/29090987/",
    "setting": "Exercise",
    "devices": "Apple Watch",
    "reference": "Polar T31 chest strap",
    "people": 15,
    "finding": "Maximum heart rate during a treadmill test correlated with the strap at 0.87 and 0.98 for two watches worn on opposite wrists.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-29210326",
    "title": "Comparative evaluation of heart rate-based monitors: Apple Watch vs Fitbit Charge HR.",
    "citation": "Bai Y et al.",
    "year": 2018,
    "doi": "10.1080/02640414.2017.1412235",
    "pmid": "29210326",
    "url": "https://pubmed.ncbi.nlm.nih.gov/29210326/",
    "setting": "Exercise",
    "devices": "Apple Watch, Fitbit Charge HR",
    "reference": "Polar ECG chest strap",
    "people": 39,
    "finding": "Fitbit mean absolute percentage error was 7.2% when sedentary, 8.4% during aerobic exercise and 10.1% during light activity.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-29489850",
    "title": "Assessment of the Fitbit Charge 2 for monitoring heart rate.",
    "citation": "Benedetto S et al.",
    "year": 2018,
    "doi": "10.1371/journal.pone.0192691",
    "pmid": "29489850",
    "url": "https://pubmed.ncbi.nlm.nih.gov/29489850/",
    "setting": "Exercise",
    "devices": "Fitbit Charge 2",
    "reference": "ECG",
    "people": 15,
    "finding": "During stationary cycling, Fitbit averaged 5.9 bpm low, with limits of agreement from −28.5 to +16.8 bpm.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-29189666",
    "title": "Validity of Wearable Activity Monitors during Cycling and Resistance Exercise.",
    "citation": "Boudreaux BD et al.",
    "year": 2018,
    "doi": "10.1249/mss.0000000000001471",
    "pmid": "29189666",
    "url": "https://pubmed.ncbi.nlm.nih.gov/29189666/",
    "setting": "Exercise",
    "devices": "Apple Watch Series 2, Fitbit Blaze, Fitbit Charge 2, Polar H7, Polar A360, Garmin Vivosmart HR, TomTom Touch, Bose SoundSport Pulse",
    "reference": "ECG",
    "people": 50,
    "finding": "In cycling, Apple Watch had 4.14% mean absolute percentage error. The Bose earbuds had 6.24% in the resistance exercise results.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-29856730",
    "title": "Monitoring of heart rate and inter-beat intervals with wrist plethysmography in patients with atrial fibrillation",
    "citation": "Harju J et al.",
    "year": 2018,
    "doi": "10.1088/1361-6579/aac9a9",
    "pmid": "29856730",
    "url": "https://pubmed.ncbi.nlm.nih.gov/29856730/",
    "setting": "Clinical",
    "devices": "Dual-wavelength wrist PPG monitor",
    "reference": "Standard ECG",
    "people": null,
    "finding": "Mean absolute error was 1.50 bpm in sinus rhythm and 4.28 bpm in atrial fibrillation.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-29887428",
    "title": "Smart watches for heart rate assessment in atrial arrhythmias.",
    "citation": "Koshy AN et al.",
    "year": 2018,
    "doi": "10.1016/j.ijcard.2018.02.073",
    "pmid": "29887428",
    "url": "https://pubmed.ncbi.nlm.nih.gov/29887428/",
    "setting": "Clinical",
    "devices": "Apple Watch, Fitbit",
    "reference": "Continuous ECG",
    "people": 102,
    "finding": "In sinus rhythm the reported bias was 1 bpm for both watches. In atrial arrhythmias, Spearman correlations were 0.83 for Apple Watch and 0.56 for Fitbit.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-29518020",
    "title": "Accuracy of a Wrist-Worn Heart Rate Sensing Device during Elective Pediatric Surgical Procedures.",
    "citation": "Pelizzo G et al.",
    "year": 2018,
    "doi": "10.3390/children5030038",
    "pmid": "29518020",
    "url": "https://pubmed.ncbi.nlm.nih.gov/29518020/",
    "setting": "Clinical",
    "devices": "Fitbit Charge HR",
    "reference": "Continuous ECG",
    "people": 30,
    "finding": "Pearson correlation with ECG was 0.99 around elective pediatric surgery.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-30530451",
    "title": "Accuracy of Wrist-Worn Activity Monitors During Common Daily Physical Activities and Types of Structured Exercise: Evaluation Study.",
    "citation": "Reddy RK et al.",
    "year": 2018,
    "doi": "10.2196/10338",
    "pmid": "30530451",
    "url": "https://pubmed.ncbi.nlm.nih.gov/30530451/",
    "setting": "Exercise",
    "devices": "Fitbit Charge 2, Garmin Vivosmart HR+",
    "reference": "Polar ECG chest strap",
    "people": 20,
    "finding": "Across structured exercise and daily tasks, signed relative error averaged −4.7% for Fitbit and −3.3% for Garmin.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-29881626",
    "title": "Wrist-worn optical and chest strap heart rate comparison in a heterogeneous sample of healthy individuals and in coronary artery disease patients.",
    "citation": "Sartor F et al.",
    "year": 2018,
    "doi": "10.1186/s13102-018-0098-0",
    "pmid": "29881626",
    "url": "https://pubmed.ncbi.nlm.nih.gov/29881626/",
    "setting": "Exercise",
    "devices": "Wrist optical heart-rate monitor",
    "reference": "ECG chest strap",
    "people": null,
    "finding": "About 92% of readings were within 10 bpm during gym activities and 98% during sedentary activity.",
    "locator": "Abstract",
    "evidence": "Manufacturer involvement",
    "resultsStudy": null
  },
  {
    "id": "pmid-30539120",
    "title": "The Polar ® OH1 Optical Heart Rate Sensor is Valid during Moderate-Vigorous Exercise",
    "citation": "Schubert MM et al.",
    "year": 2018,
    "doi": "10.1055/a-0631-0920",
    "pmid": "30539120",
    "url": "https://pubmed.ncbi.nlm.nih.gov/30539120/",
    "setting": "Exercise",
    "devices": "Polar OH1",
    "reference": "Polar H7",
    "people": 15,
    "finding": "The upper-arm sensor had a mean bias of 0.76 bpm and a typical error of 2.42 bpm during power vinyasa yoga.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-29942628",
    "title": "Validity of wrist-worn consumer products to measure heart rate and energy expenditure.",
    "citation": "Thiebaud RS et al.",
    "year": 2018,
    "doi": "10.1177/2055207618770322",
    "pmid": "29942628",
    "url": "https://pubmed.ncbi.nlm.nih.gov/29942628/",
    "setting": "Exercise",
    "devices": "Fitbit Surge, TomTom Cardio, Microsoft Band",
    "reference": "3-lead ECG",
    "people": null,
    "finding": "Treadmill mean absolute percentage error ranged from 2.17% to 8.06% for Fitbit Surge and 1.01% to 7.49% for TomTom Cardio.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-28675070",
    "title": "Validity of heart rate measurements by the Garmin Forerunner 225 at different walking intensities.",
    "citation": "Claes J et al.",
    "year": 2017,
    "doi": "10.1080/03091902.2017.1333166",
    "pmid": "28675070",
    "url": "https://pubmed.ncbi.nlm.nih.gov/28675070/",
    "setting": "Exercise",
    "devices": "Garmin Forerunner 225",
    "reference": "Zensor 3-lead ECG",
    "people": 12,
    "finding": "Root mean squared error was 3.01 bpm using three-minute averages at different walking intensities.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-27537777",
    "title": "Evaluation of Reliability of MYZONE MZ-3 Heart Rate Monitor: A Study for the Future of Telephysiotherapy for Preoperative Prehabilitation in Cancer Patients",
    "citation": "Cuadros L et al.",
    "year": 2017,
    "doi": "10.1089/tmj.2016.0138",
    "pmid": "27537777",
    "url": "https://pubmed.ncbi.nlm.nih.gov/27537777/",
    "setting": "Exercise",
    "devices": "MYZONE MZ-3",
    "reference": "ECG",
    "people": 7,
    "finding": "Across 1,928 pairs, the study reported a mean difference of 0.4 bpm and adjusted limits of agreement of −4.5 to +5.3 bpm.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-28302596",
    "title": "Estimating Accuracy at Exercise Intensities: A Comparative Study of Self-Monitoring Heart Rate and Physical Activity Wearable Devices.",
    "citation": "Dooley EE et al.",
    "year": 2017,
    "doi": "10.2196/mhealth.7043",
    "pmid": "28302596",
    "url": "https://pubmed.ncbi.nlm.nih.gov/28302596/",
    "setting": "Exercise",
    "devices": "Apple Watch, Fitbit Charge HR, Garmin Forerunner 225",
    "reference": "ECG chest strap",
    "people": 62,
    "finding": "Apple Watch heart-rate MAPE ranged from 1.14% to 6.70% across the treadmill and rest protocol.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-28709155",
    "title": "Variable Accuracy of Wearable Heart Rate Monitors during Aerobic Exercise.",
    "citation": "Gillinov S et al.",
    "year": 2017,
    "doi": "10.1249/mss.0000000000001284",
    "pmid": "28709155",
    "url": "https://pubmed.ncbi.nlm.nih.gov/28709155/",
    "setting": "Exercise",
    "devices": "Apple Watch, TomTom Spark Cardio, Garmin Forerunner 235, Fitbit Blaze, Scosche Rhythm+, Polar H7",
    "reference": "ECG",
    "people": 50,
    "finding": "During treadmill exercise in healthy adults, the Fitbit Blaze read 5.9 bpm low and the TomTom Spark Cardio read 1.4 bpm low on average. Each wrist model was assigned to 25 participants.",
    "locator": "Table 2 and statistical methods",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-29055881",
    "title": "Fitbit Charge HR Wireless Heart Rate Monitor: Validation Study Conducted Under Free-Living Conditions.",
    "citation": "Gorny AW et al.",
    "year": 2017,
    "doi": "10.2196/mhealth.8233",
    "pmid": "29055881",
    "url": "https://pubmed.ncbi.nlm.nih.gov/29055881/",
    "setting": "Daily life",
    "devices": "Fitbit Charge HR",
    "reference": "Polar H6",
    "people": 10,
    "finding": "One-minute Fitbit averages were 5.96 bpm low overall and 16.2 bpm low in the moderate-to-vigorous heart-rate zone.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-28153815",
    "title": "Clinical Evaluation of the Measurement Performance of the Philips Health Watch: A Within-Person Comparative Study",
    "citation": "Hendrikx J et al.",
    "year": 2017,
    "doi": "10.2196/mhealth.6893",
    "pmid": "28153815",
    "url": "https://pubmed.ncbi.nlm.nih.gov/28153815/",
    "setting": "Daily life",
    "devices": "Philips Health Watch",
    "reference": "Wearable ECG",
    "people": 29,
    "finding": "Resting heart rate matched ECG on average. Across the daily-task protocol, the watch was within the study’s 10 bpm and 10% tolerance for 93% of the time.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-29135785",
    "title": "Comparison of Polar M600 Optical Heart Rate and ECG Heart Rate during Exercise.",
    "citation": "Horton JF et al.",
    "year": 2017,
    "doi": "10.1249/mss.0000000000001388",
    "pmid": "29135785",
    "url": "https://pubmed.ncbi.nlm.nih.gov/29135785/",
    "setting": "Exercise",
    "devices": "Polar M600",
    "reference": "3-lead ECG",
    "people": 36,
    "finding": "The watch stayed within 5 bpm of ECG for 91.8% of the cycling interval readings and 34.5% of the circuit weight training readings.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-30539109",
    "title": "Validity and Reliability of the Apple Watch for Measuring Heart Rate During Exercise.",
    "citation": "Khushhal A et al.",
    "year": 2017,
    "doi": "10.1055/s-0043-120195",
    "pmid": "30539109",
    "url": "https://pubmed.ncbi.nlm.nih.gov/30539109/",
    "setting": "Exercise",
    "devices": "Apple Watch Series 0",
    "reference": "Polar S810i chest strap",
    "people": 21,
    "finding": "Correlations with the chest strap fell from 0.97 during walking to 0.81 and 0.86 during running for the watches worn on opposite wrists.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-28743682",
    "title": "Estimating Heart Rate, Energy Expenditure, and Physical Performance With a Wrist Photoplethysmographic Device During Running",
    "citation": "Parak J et al.",
    "year": 2017,
    "doi": "10.2196/mhealth.7437",
    "pmid": "28743682",
    "url": "https://pubmed.ncbi.nlm.nih.gov/28743682/",
    "setting": "Exercise",
    "devices": "PulseOn wrist monitor",
    "reference": "ECG-derived heart rate",
    "people": 24,
    "finding": "Wrist optical heart rate during running had mean absolute percentage error of 1.9%.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-28400221",
    "title": "Validation of a Self-Monitoring Tool for Use in Exercise Therapy.",
    "citation": "Powierza CS et al.",
    "year": 2017,
    "doi": "10.1016/j.pmrj.2017.03.012",
    "pmid": "28400221",
    "url": "https://pubmed.ncbi.nlm.nih.gov/28400221/",
    "setting": "Exercise",
    "devices": "Fitbit Charge HR",
    "reference": "ECG",
    "people": 22,
    "finding": "Mean bias was −6.04 bpm during a treadmill protocol, and 69.9% of readings were within 10% of ECG.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-28538708",
    "title": "Accuracy in Wrist-Worn, Sensor-Based Measurements of Heart Rate and Energy Expenditure in a Diverse Cohort.",
    "citation": "Shcherbina A et al.",
    "year": 2017,
    "doi": "10.3390/jpm7020003",
    "pmid": "28538708",
    "url": "https://pubmed.ncbi.nlm.nih.gov/28538708/",
    "setting": "Exercise",
    "devices": "Apple Watch, Basis Peak, Fitbit Surge, Microsoft Band, Mio Alpha 2, PulseOn, Samsung Gear S2",
    "reference": "Continuous ECG telemetry",
    "people": 60,
    "finding": "Six of seven trackers had median heart-rate error below 5% when cycling. Walking generally produced larger errors.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-28166774",
    "title": "Highly wearable cuff-less blood pressure and heart rate monitoring with single-arm electrocardiogram and photoplethysmogram signals",
    "citation": "Zhang Q et al.",
    "year": 2017,
    "doi": "10.1186/s12938-017-0317-z",
    "pmid": "28166774",
    "url": "https://pubmed.ncbi.nlm.nih.gov/28166774/",
    "setting": "Sleep and rest",
    "devices": "Combined ECG and PPG upper-arm band",
    "reference": "Chest ECG",
    "people": 10,
    "finding": "The prototype’s heart-rate algorithm had mean absolute error of 0.21 bpm and root mean square error of 1.20 bpm in a proof-of-concept test.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-27177545",
    "title": "Design and evaluation of a ubiquitous chest-worn cardiopulmonary monitoring system for healthcare application: a pilot study",
    "citation": "Zheng J et al.",
    "year": 2017,
    "doi": "10.1007/s11517-016-1518-5",
    "pmid": "27177545",
    "url": "https://pubmed.ncbi.nlm.nih.gov/27177545/",
    "setting": "Exercise",
    "devices": "Chest-worn cardiopulmonary monitoring prototype",
    "reference": "Clinical reference ECG",
    "people": null,
    "finding": "Mean heart-rate bias was 0.60 bpm in the staged treadmill test. Agreement narrowed at slower speeds.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-27708585",
    "title": "Comparative Analysis of the Equivital EQ02 Lifemonitor with Holter Ambulatory ECG Device for Continuous Measurement of ECG, Heart Rate, and Heart Rate Variability: A Validation Study for Precision and Accuracy",
    "citation": "Akintola AA et al.",
    "year": 2016,
    "doi": "10.3389/fphys.2016.00391",
    "pmid": "27708585",
    "url": "https://pubmed.ncbi.nlm.nih.gov/27708585/",
    "setting": "Daily life",
    "devices": "Equivital EQ02",
    "reference": "24-hour Holter ECG",
    "people": 18,
    "finding": "As more artifact-contaminated data were excluded, the reported correlation with Holter increased from 0.72 to 1.00 after rounding.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-28268977",
    "title": "Estimation of heart rate from foot worn photoplethysmography sensors during fast bike exercise",
    "citation": "Jarchi D et al.",
    "year": 2016,
    "doi": "10.1109/embc.2016.7591398",
    "pmid": "28268977",
    "url": "https://pubmed.ncbi.nlm.nih.gov/28268977/",
    "setting": "Exercise",
    "devices": "Foot-worn PPG prototype",
    "reference": "ECG",
    "people": 8,
    "finding": "An algorithm estimating heart rate from optical sensors on the foot averaged 9 bpm of error during fast cycling.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-27803634",
    "title": "Validation of Biofeedback Wearables for Photoplethysmographic Heart Rate Tracking.",
    "citation": "Jo E et al.",
    "year": 2016,
    "doi": null,
    "pmid": "27803634",
    "url": "https://pubmed.ncbi.nlm.nih.gov/27803634/",
    "setting": "Exercise",
    "devices": "Basis Peak, Fitbit Charge HR",
    "reference": "12-lead ECG",
    "people": 24,
    "finding": "Above 116 bpm on ECG, mean bias was −4.9 bpm for Basis Peak and −12.7 bpm for Fitbit Charge HR.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-27651304",
    "title": "Accuracy of a Wrist-Worn Wearable Device for Monitoring Heart Rates in Hospital Inpatients: A Prospective Observational Study",
    "citation": "Kroll RR et al.",
    "year": 2016,
    "doi": "10.2196/jmir.6025",
    "pmid": "27651304",
    "url": "https://pubmed.ncbi.nlm.nih.gov/27651304/",
    "setting": "Clinical",
    "devices": "Fitbit Charge HR",
    "reference": "Continuous bedside ECG",
    "people": 50,
    "finding": "In stable intensive-care patients, mean bias was −1.14 bpm overall. It was −0.99 bpm in sinus rhythm and −5.02 bpm in other rhythms.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-27900173",
    "title": "How accurate are the wrist-based heart rate monitors during walking and running activities? Are they accurate enough?",
    "citation": "Stahl SE et al.",
    "year": 2016,
    "doi": "10.1136/bmjsem-2015-000106",
    "pmid": "27900173",
    "url": "https://pubmed.ncbi.nlm.nih.gov/27900173/",
    "setting": "Exercise",
    "devices": "Scosche Rhythm, Mio Alpha, Fitbit Charge HR, Basis Peak, Microsoft Band, TomTom Runner Cardio",
    "reference": "Polar RS400 chest strap",
    "people": 50,
    "finding": "Mean absolute percentage error ranged from 3.3% for TomTom to 6.2% for Fitbit during treadmill walking and running.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-27232714",
    "title": "Accuracy of Heart Rate Watches: Implications for Weight Management.",
    "citation": "Wallen MP et al.",
    "year": 2016,
    "doi": "10.1371/journal.pone.0154420",
    "pmid": "27232714",
    "url": "https://pubmed.ncbi.nlm.nih.gov/27232714/",
    "setting": "Exercise",
    "devices": "Apple Watch, Fitbit Charge HR, Samsung Gear S, Mio Alpha",
    "reference": "ECG",
    "people": 22,
    "finding": "Reported heart-rate percentage error ranged from 1% to 9% across four models during rest and exercise.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-26554432",
    "title": "Evaluation of a strapless heart rate monitor during simulated flight tasks",
    "citation": "Wang Z et al.",
    "year": 2016,
    "doi": "10.1080/15459624.2015.1101121",
    "pmid": "26554432",
    "url": "https://pubmed.ncbi.nlm.nih.gov/26554432/",
    "setting": "Daily life",
    "devices": "Strapless optical heart-rate watch",
    "reference": "Criterion ECG",
    "people": 10,
    "finding": "In flight-simulator tasks with commercial pilots, the watch averaged 0.71 bpm below ECG.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-26736291",
    "title": "Evaluation of accuracy and reliability of PulseOn optical heart rate monitoring device.",
    "citation": "Delgado-Gonzalo R et al.",
    "year": 2015,
    "doi": "10.1109/embc.2015.7318391",
    "pmid": "26736291",
    "url": "https://pubmed.ncbi.nlm.nih.gov/26736291/",
    "setting": "Exercise",
    "devices": "PulseOn, Mio Link",
    "reference": "ECG",
    "people": null,
    "finding": "Laboratory readings were less than 10 bpm off 94.5% of the time for PulseOn and 86.6% for Mio Link.",
    "locator": "Abstract",
    "evidence": "Manufacturer involvement",
    "resultsStudy": null
  },
  {
    "id": "pmid-26703618",
    "title": "A Novel Time-Varying Spectral Filtering Algorithm for Reconstruction of Motion Artifact Corrupted Heart Rate Signals During Intense Physical Activities Using a Wearable Photoplethysmogram Sensor",
    "citation": "Salehizadeh SM et al.",
    "year": 2015,
    "doi": "10.3390/s16010010",
    "pmid": "26703618",
    "url": "https://pubmed.ncbi.nlm.nih.gov/26703618/",
    "setting": "Exercise",
    "devices": "Optical wearable with SpaMA offline processing",
    "reference": "ECG",
    "people": 10,
    "finding": "On the separately collected lab treadmill data, average heart-rate error was 1.38 bpm. The study also tested the same method on previously published data.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-26112379",
    "title": "Validation of photoplethysmography as a method to detect heart rate during rest and exercise.",
    "citation": "Spierer DK et al.",
    "year": 2015,
    "doi": "10.3109/03091902.2015.1047536",
    "pmid": "26112379",
    "url": "https://pubmed.ncbi.nlm.nih.gov/26112379/",
    "setting": "Exercise",
    "devices": "Mio Alpha, Omron HR500U",
    "reference": "Polar RS800CX chest strap",
    "people": 47,
    "finding": "The reported difference for Mio Alpha during weight lifting was 23.30 bpm; for the Omron it was 4.67 bpm.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-25812938",
    "title": "Using photoplethysmography in heart rate monitoring of patients with epilepsy",
    "citation": "van Andel J et al.",
    "year": 2015,
    "doi": "10.1016/j.yebeh.2015.02.018",
    "pmid": "25812938",
    "url": "https://pubmed.ncbi.nlm.nih.gov/25812938/",
    "setting": "Sleep and rest",
    "devices": "Commercial optical heart-rate monitor",
    "reference": "ECG",
    "people": 7,
    "finding": "In overnight epilepsy monitoring, agreement limits grew wider during wakefulness and two recorded seizures than during sleep.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-26360814",
    "title": "Validation of the Hexoskin wearable vest during lying, sitting, standing, and walking activities",
    "citation": "Villar R et al.",
    "year": 2015,
    "doi": "10.1139/apnm-2015-0140",
    "pmid": "26360814",
    "url": "https://pubmed.ncbi.nlm.nih.gov/26360814/",
    "setting": "Daily life",
    "devices": "Hexoskin smart vest",
    "reference": "Laboratory reference monitor",
    "people": 20,
    "finding": "During changes in posture and walking speed, the mean heart-rate difference was close to zero with relatively little spread in the group.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-24896644",
    "title": "Validation of heart rate derived from a physiological status monitor-embedded compression shirt against criterion ECG",
    "citation": "Dolezal BA et al.",
    "year": 2014,
    "doi": "10.1080/15459624.2014.925114",
    "pmid": "24896644",
    "url": "https://pubmed.ncbi.nlm.nih.gov/24896644/",
    "setting": "Exercise",
    "devices": "Physiological Status Monitor compression shirt",
    "reference": "12-lead ECG",
    "people": 10,
    "finding": "In four simulated firefighting activities, pooled heart rates correlated above 0.99 with ECG. The standard error of estimate was 0.84 bpm.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-23860286",
    "title": "Concurrent validity of the Armour39 heart rate monitor strap",
    "citation": "Flanagan SD et al.",
    "year": 2014,
    "doi": "10.1519/jsc.0b013e3182a16d38",
    "pmid": "23860286",
    "url": "https://pubmed.ncbi.nlm.nih.gov/23860286/",
    "setting": "Exercise",
    "devices": "Under Armour Armour39 strap",
    "reference": "ECG",
    "people": 75,
    "finding": "During graded cycling, the strap and ECG typically differed by about one beat per minute. Stage-level correlations were at least 0.99.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-24742972",
    "title": "Forehead reflectance photoplethysmography to monitor heart rate: preliminary results from neonatal patients",
    "citation": "Grubb MR et al.",
    "year": 2014,
    "doi": "10.1088/0967-3334/35/5/881",
    "pmid": "24742972",
    "url": "https://pubmed.ncbi.nlm.nih.gov/24742972/",
    "setting": "Clinical",
    "devices": "Forehead reflectance pulse sensor",
    "reference": "ECG",
    "people": 77,
    "finding": "In infants born at 32 weeks or later, the median share of readings within 10 bpm was 97.7%, compared with 94.8% in more premature infants.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-24110039",
    "title": "Comparison between red, green and blue light reflection photoplethysmography for heart rate monitoring during motion",
    "citation": "Lee J et al.",
    "year": 2013,
    "doi": "10.1109/embc.2013.6609852",
    "pmid": "24110039",
    "url": "https://pubmed.ncbi.nlm.nih.gov/24110039/",
    "setting": "Daily life",
    "devices": "Prototype reflective PPG monitor",
    "reference": "ECG",
    "people": 12,
    "finding": "During hand waving, the agreement range was narrowest using green light, at 0.61 bpm on either side of the reported bias.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-15714212",
    "title": "Reliability and validity of the combined heart rate and movement sensor Actiheart",
    "citation": "Brage S et al.",
    "year": 2005,
    "doi": "10.1038/sj.ejcn.1602118",
    "pmid": "15714212",
    "url": "https://pubmed.ncbi.nlm.nih.gov/15714212/",
    "setting": "Exercise",
    "devices": "Actiheart",
    "reference": "ECG",
    "people": 20,
    "finding": "Across rest and treadmill speeds from walking to running, the agreement limits were −4.2 to +4.3 bpm.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-9115087",
    "title": "Validity of a heart rate monitor during work in the laboratory and on the Space Shuttle",
    "citation": "Moore AD et al.",
    "year": 1997,
    "doi": "10.1080/15428119791012829",
    "pmid": "9115087",
    "url": "https://pubmed.ncbi.nlm.nih.gov/9115087/",
    "setting": "Exercise",
    "devices": "Commercial heart-rate monitor",
    "reference": "Simultaneous ECG",
    "people": 18,
    "finding": "During lab work and astronaut cycling in flight, monitor and ECG values both had coefficients of determination of 0.99.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-27403554",
    "title": "Heart Rate Monitors: Validity, Stability, and Functionality",
    "citation": "Léger L et al.",
    "year": 1988,
    "doi": "10.1080/00913847.1988.11709511",
    "pmid": "27403554",
    "url": "https://pubmed.ncbi.nlm.nih.gov/27403554/",
    "setting": "Exercise",
    "devices": "13 commercial heart-rate monitors",
    "reference": "Simultaneous ECG",
    "people": null,
    "finding": "In a 1988 comparison, monitors using conventional chest electrodes tracked ECG most closely.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "pmid-6478343",
    "title": "Evaluation of commercially available heart rate monitors",
    "citation": "Humen DP et al.",
    "year": 1984,
    "doi": null,
    "pmid": "6478343",
    "url": "https://pubmed.ncbi.nlm.nih.gov/6478343/",
    "setting": "Exercise",
    "devices": "Nine commercially available heart-rate monitors",
    "reference": "Single-lead ECG",
    "people": 16,
    "finding": "In this 1984 cycling test, three-electrode devices and the light-transmission earlobe monitor were the closest to ECG.",
    "locator": "Abstract",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "odriscoll-2020",
    "title": "The validity of two widely used commercial and research-grade activity monitors, during resting, household and activity behaviours",
    "citation": "O’Driscoll R et al.",
    "year": 2020,
    "doi": "10.1007/s12553-019-00392-7",
    "pmid": null,
    "url": "https://eprints.whiterose.ac.uk/id/eprint/177301/1/ODriscoll2020_Article_TheValidityOfTwoWidelyUsedComm.pdf",
    "setting": "Treadmill, stationary cycling, rest and household tasks",
    "devices": "Fitbit Charge 2",
    "reference": "Polar H7 chest strap",
    "people": 59,
    "finding": "The Charge 2’s mean absolute heart-rate error was 19.50 bpm while walking on the treadmill and 10.02 bpm while running. The reference and watch were compared at one-minute resolution.",
    "locator": "Table 3",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "de-leon-2026",
    "title": "Accuracy of the Garmin Vivoactive 4 for Estimating Heart Rate, Energy Expenditure, and Step Count During Treadmill Exercise",
    "citation": "de Leon MF et al.",
    "year": 2026,
    "doi": "10.3390/app16031286",
    "pmid": null,
    "url": "https://www.mdpi.com/2076-3417/16/3/1286",
    "setting": "Exercise",
    "devices": "Garmin Vivoactive 4",
    "reference": "12-lead ECG",
    "people": 18,
    "finding": "Mean absolute heart-rate error was 13.0%. The watch averaged 17.4 bpm low, but tended to read high below about 120 bpm and low above about 150 bpm.",
    "locator": "Section 3.1 and Figure 2",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "ryan-intervals-2026",
    "title": "The Agreement of Wrist-based Apple Watch and Polar Grit Heart Rate Monitoring as Compared With Chest-strap Polar Monitor",
    "citation": "Ryan MM et al.",
    "year": 2026,
    "doi": "10.1249/TJX.0000000000000379",
    "pmid": null,
    "url": "https://www.ovid.com/jnls/acsm-tj/fulltext/10.1249/tjx.0000000000000379~the-agreement-of-wrist-based-apple-watch-and-polar-grit",
    "setting": "Exercise",
    "devices": "Apple Watch Series 8, Polar Grit X",
    "reference": "Polar H10",
    "people": 25,
    "finding": "Mean absolute error across treadmill stages ranged from 3.2 to 5.9 bpm for Apple Watch Series 8 and 10.5 to 14.5 bpm for Polar Grit X. Apple readings were interpolated to one second.",
    "locator": "Tables 1 and 3",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "balogh-treadmill-2026",
    "title": "Accuracy of Wearable Heart Rate Monitors under Static and High-Intensity Activity Conditions",
    "citation": "Balogh JD and Adamkó A",
    "year": 2026,
    "doi": "10.17048/icai.2026.48",
    "pmid": null,
    "url": "https://publikacio.uni-eszterhazy.hu/9434/1/ICAI2026-pp48-54.pdf",
    "setting": "Exercise",
    "devices": "Apple Watch Series 8, Garmin Forerunner 265, Samsung Galaxy Watch 6, Xiaomi Smart Band 8",
    "reference": "Ambulatory Holter ECG (model unspecified)",
    "people": 30,
    "finding": "Mean absolute errors in the dynamic phase were 8.5 bpm for Apple Watch Series 8, 9.2 for Garmin Forerunner 265, 14.5 for Galaxy Watch 6 and 16.1 for Xiaomi Smart Band 8.",
    "locator": "Table 1 and protocol §2.3",
    "evidence": "Conference proceedings",
    "resultsStudy": null
  },
  {
    "id": "pmid-42076635",
    "title": "Comparative Validity of Smartwatch-Derived Heart Rate and Energy Expenditure During Endurance and Resistance Exercise",
    "citation": "Lee TH et al.",
    "year": 2026,
    "doi": "10.3390/s26082526",
    "pmid": "42076635",
    "url": "https://www.mdpi.com/1424-8220/26/8/2526",
    "setting": "Exercise",
    "devices": "Apple Watch Series 7, Samsung Galaxy Watch 4, Fitbit Charge 5, Garmin Vivosmart 5",
    "reference": "Quinton Q-Stress ECG",
    "people": 62,
    "finding": "For the reported endurance protocol means, signed differences ranged from 0.97 bpm low on Apple Watch Series 7 to 1.08 bpm high on Fitbit Charge 5. These are summary estimates.",
    "locator": "Sections 3.1.4 and 3.2.4, Figures 4 and 7",
    "evidence": "SOLUM-funded study",
    "resultsStudy": null
  },
  {
    "id": "tao-ringconn-2026",
    "title": "Method comparison of a ring-based PPG device and a chest-strap monitor for heart rate and heart rate variability in shooting athletes",
    "citation": "Tao L et al.",
    "year": 2026,
    "doi": "10.1186/s13102-026-01960-x",
    "pmid": null,
    "url": "https://link.springer.com/article/10.1186/s13102-026-01960-x",
    "setting": "Sleep and rest",
    "devices": "RingConn Gen 2",
    "reference": "Polar H10",
    "people": 64,
    "finding": "Heart rate estimated from research-mode RingConn Gen 2 signals averaged 0.42 bpm low during seated post-training recovery. The comparison used participant averages.",
    "locator": "Results, Figure 3",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "radev-driving-2026",
    "title": "Validation of Commercial Wearables for Driver Monitoring: Assessing Heart Rate Accuracy and Reliability for Early Detection of Sudden Illnesses",
    "citation": "Radev H and Petrova G",
    "year": 2026,
    "doi": "10.3390/app162010201",
    "pmid": null,
    "url": "https://www.mdpi.com/2076-3417/16/20/10201",
    "setting": "Daily life",
    "devices": "Huawei Watch D2, Oura Ring Gen 3, Xmart Ring",
    "reference": "CardioBAN BLE Lead I ECG",
    "people": 21,
    "finding": "Across 19 retained driving sessions, mean session absolute errors were 2.73 bpm for Huawei Watch D2 and 3.73 bpm for Oura Ring Gen 3. Ring fitting and missingness varied by session.",
    "locator": "Table 4 and Figure 3",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "merrigan-rucking-2023",
    "title": "Validation of Garmin and Polar Devices for Continuous Heart Rate Monitoring During Common Training Movements in Tactical Populations",
    "citation": "Merrigan JJ et al.",
    "year": 2023,
    "doi": "10.1080/1091367X.2022.2161820",
    "pmid": null,
    "url": "https://www.tandfonline.com/doi/full/10.1080/1091367X.2022.2161820",
    "setting": "Exercise",
    "devices": "Polar H10, Garmin HRM-Pro, Polar Verity Sense, Garmin Fenix 6, Polar Grit X",
    "reference": "Bittium Faros 180 multi-lead ECG",
    "people": 8,
    "finding": "Polar Grit X averaged 9.26% and 16.45% absolute error in two weighted treadmill walking protocols. Garmin Fenix 6 averaged 5.44% and 4.44% in the same protocols.",
    "locator": "Tables 1–4",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "shimizu-oura-2025",
    "title": "Validation of exercise heart rate measurement accuracy using the Oura Ring",
    "citation": "Shimizu J",
    "year": 2025,
    "doi": "10.82713/sit.2025.0_P-2-8",
    "pmid": null,
    "url": "https://www.jstage.jst.go.jp/article/sit/2025/0/2025_P-2-8/_article/-char/en",
    "setting": "Exercise",
    "devices": "Oura Ring Gen 3",
    "reference": "Polar H10",
    "people": 1,
    "finding": "A single participant’s mean absolute error was 2.56 bpm during treadmill running, 7.86 bpm during outdoor cycling and 7.31 bpm during lifting. The source labels those three activities separately in Table 1.",
    "locator": "Table 1 and Figures 1–3",
    "evidence": "Conference proceedings",
    "resultsStudy": null
  },
  {
    "id": "whitney-2025-bmes",
    "title": "Quantifying Heart Rate Error in Consumer Wearables: Effects of Skin Tone, Exertion, and Sensor Modality on Accuracy",
    "citation": "Whitney H et al.",
    "year": 2025,
    "doi": null,
    "pmid": null,
    "url": "https://2025bmes.eventscribe.net/fsPopup.asp?PresentationID=1702118&mode=presInfo",
    "setting": "Exercise",
    "devices": "Garmin Fenix 7, WHOOP 4.0, Polar H10",
    "reference": "GE Dash 5000 clinical ECG",
    "people": 73,
    "finding": "The 46 athletes with matched results were a subset of 73 recruited. The abstract compares agreement and dropout but omits standalone device error in bpm.",
    "locator": "Conference abstract; possible overlap with the smaller Lehigh report",
    "evidence": "Conference abstract",
    "resultsStudy": null
  },
  {
    "id": "oropesa-treadmill-2026",
    "title": "Are We Really Training at the Desired Intensity? Concurrent Validity of 16 Commercial Photoplethysmography-Based Heart Rate Monitors",
    "citation": "Oropesa P et al.",
    "year": 2026,
    "doi": "10.3390/app16010126",
    "pmid": null,
    "url": "https://www.mdpi.com/2076-3417/16/1/126",
    "setting": "Exercise",
    "devices": "Amazfit Bip 5, Apple Watch SE, Apple Watch Ultra, Garmin Forerunner 235, Garmin Forerunner 35, Garmin Forerunner 45, Garmin Forerunner 935, Polar M200, Polar M430, Polar OH1, Polar Vantage M, Polar Vantage V, Polar Vantage V3, Polar Verity Sense, Samsung Galaxy Watch 5, Suunto 3 Fitness",
    "reference": "Polar H9 ECG chest strap",
    "people": 10,
    "finding": "Apple Watch SE and Ultra averaged 0 bpm of signed difference over each complete treadmill protocol, rounded to the nearest bpm. Both were 1 bpm low during high-intensity intervals. Readings more than 30% from the reference were removed before analysis.",
    "locator": "Tables 1–3 and section 2.3.5",
    "evidence": "Published research",
    "resultsStudy": null
  },
  {
    "id": "rollins-mixed-exercise-2026",
    "title": "Heart Rate Accuracy Across Wearable Devices and Exercise Intensity Spectrum: A Pilot Study",
    "citation": "Rollins IG et al.",
    "year": 2026,
    "doi": null,
    "pmid": null,
    "url": "https://southeast.acsm.org/wp-content/uploads/2026/02/SEACSM-2026-program-ABSTRACTS-2-21-26.pdf",
    "setting": "Exercise",
    "devices": "Apple Watch Series 5, Garmin Vivosmart 4, Fitbit Inspire HR, Empatica EmbracePlus",
    "reference": "Polar H9 ECG chest strap",
    "people": 26,
    "finding": "Across tasks from rest through running and active gaming, Apple Watch Series 5 averaged 2.41 bpm low and Garmin Vivosmart 4 averaged 0.82 bpm high. The abstract has inconsistent reporting for Fitbit and Empatica.",
    "locator": "Conference abstract M6, printed page 93",
    "evidence": "Conference abstract",
    "resultsStudy": null
  }
]