Wearable heart rate accuracy dataset

The library includes 223 studies. The combined table uses device-level numbers from 139 of them. Read the report.

Heart rate accuracy by device

1,270 device results from 139 studies.

35 ranked · 78 devices · 38 studiesDownload combined data

Error shows how far off the device was. Reads high or low shows whether its readings averaged above or below the reference.

10.67 bpm1PreliminaryNear even−0.18 bpm1 study
20.78 bpm1PreliminaryLow−1.52 bpm2 studies
30.9 bpm1PreliminaryNear even+0.1 bpm1 study
40.92 bpm2Near even−0.29 bpm2 studies
50.99 bpm1PreliminaryLow−1.34 bpm2 studies
61.18 bpm1PreliminaryNear even−0.31 bpm1 study
7Generation unspecified · Jeong Y et al. (2026)1.78 bpm1PreliminaryNear even+0.05 bpm1 study
81.81 bpm1PreliminaryNear even+0.14 bpm4 studies
91.9 bpm1PreliminaryLow−0.99 bpm2 studies
101.94 bpm1PreliminaryLow−0.61 bpm1 study
112.08 bpm1PreliminaryNear even−0.03 bpm1 study
122.6 bpm1PreliminaryLow−2.1 bpm1 study

Lower error ranks higher for the selected activity and error measure. A one-study rank is preliminary.

How the studies are combined

We extracted absolute errors from 98 studies. Each study contributes one estimate per device. Treadmill results include supervised clinical tests. We use the whole test when available, or the median across its speed or intensity stages.

We average the study estimates. The weight is the square root of the smallest reported participant count for those tests, capped at 100 participants. We use 10 participants as a weighting default when the count is unavailable. Manufacturer white papers and studies funded by a tested device maker receive half weight. With one study, that study supplies the whole estimate. Open a row to see each source’s share, or switch off weighting to give each study equal weight.

Direction summarizes signed differences in bpm against the reference. A negative value means the wearable read lower on average. Mixed means study estimates fell on both sides of zero outside a 0.5 bpm band. Near even means all the estimates fell within that band. The Studies column counts accuracy sources. Direction shows its own source count.

The ranks exclude one-person reports and results optimized by retrospectively shifting device timestamps. When a study gives only a family name or pools model variants, the row represents that study’s tested device or group. Protocols, wear sites, sampling windows and people vary. Open a row to see its original tests.

Find a study

The library covers 223 studies. Vora reanalyzed 7,518,782 paired readings from 42 people in two public datasets.

Each study has a heart-rate finding, the tested devices, the reference measurement and a link to the original work. Studies use different activities and statistics. Compare devices tested together under the same conditions.

How the studies were selected

We searched PubMed and PubMed Central via Europe PMC for human studies comparing heart rate from a wearable against ECG, ECG-derived polysomnography, or an ECG chest strap. The expanded search returned 1,663 distinct records to screen. We followed references from published reviews and included two labeled manufacturer reports with directly reported test results. We used the original abstract or the named table or figure to check each finding. Reviews, sensor simulations, tests of rhythm detection alone, and known duplicate reports of the same experiment were excluded from the count.

A study can include several devices and activities. The library shows a selected finding per study and retains its original metric. Participant counts describe the study or the sample for the shown result when available. The two public reanalysis cohorts are included in the study count. Other studies can have data available only in an abstract or a published table.

Download the data

The study library has one row per study. The combined dataset has one row per model, condition and study. Each keeps its own reference and sample. Read the analysis methods.

Cite as Vora Team, Wearable heart rate accuracy dataset, version 11, . When quoting a published value, credit the original paper. The two original datasets are released under CC BY 4.0. Free-living and lab recordings · Swimming recordings

Detailed source notes

  • Yun, Ko & Lee · Resistance exercise

    Peer-reviewed · 2026 · 70 healthy young men

    Reference: ECG display. Where to look: Tables 1 and 3.

    Four devices worn during eight sets. The authors compared displayed heart rate before each set, immediately after it, and one minute later.

    Fixed exercise order. Spot readings reflect the displayed number, including any sensor, processing or display delay. The sample was young men. No external funding or conflicts reported.

  • Vora · Treadmill reanalysis

    Public data reanalysis · 2024 · 32 adults in the source study, with device-specific paired subsets

    Reference: Medical-grade ECG. Where to look: Treadmill-running rows in the authors’ released 1 Hz files.

    Vora recalculated absolute error from the aligned ECG and sensor readings, then compared steadier and rapidly changing heart rate within each person.

    Exploratory cutoffs chosen after a pilot. The authors had already aligned device and ECG signals. Each device has its own eligible subset of people. The authors reported no conflicts. The analysis uses the public CC BY 4.0 release.

    Original data or supplement

  • Gielen et al. · Walking, stress and climate

    Peer-reviewed · 2026 · 45 adults across the study, 10 test assignments per model

    Reference: Zephyr BioHarness ECG chest strap. Where to look: Tables 1–3.

    Ten devices were compared against an ECG chest strap in a climate chamber, with steady and stop-start walking and a seated stress task. The tables give medians and middle-50% ranges of participant errors.

    Participants wore a subset of devices. Activity differences varied by model. The study did not detect a climate effect after adjustment for multiple testing. Internal KU Leuven funding. The funder reported no role in the conduct or interpretation.

  • Temple · Treadmill zones

    Manufacturer white paper · 2026 · 43 people, 42 with Fitbit Air recordings

    Reference: Taped Polar H10 ECG chest strap. Where to look: Tables 2–3 and Figure 3, pages 4, 9–10.

    Temple compared its head-worn tracker with five consumer devices during a graded treadmill protocol. Published errors average the participants’ mean absolute errors.

    The vendor tested its own device. Its main error estimates exclude defined failure episodes and missing readings. Devices logged at different frequencies. Conducted and published by Temple, maker of one tested sensor.

  • Van Oost et al. · Activity transitions

    Peer-reviewed · 2025 · 24 adults, 23 with usable 12-lead ECG

    Reference: 12-lead ECG. Where to look: Table 3 and Figure 6.

    A treadmill protocol compared steady states with changes in posture, speed, incline and stopping. Fitbit Charge 5 and Sense 2 showed higher errors during transitions in the 10-second comparison.

    Healthy university students. Shorter windows paired fewer readings for some devices. Missingness is measured relative to available ECG observations and depends on the window. Funded by Flanders Innovation & Entrepreneurship. No conflicts reported.

    Original data or supplement

  • Apple · Workout and daily living

    Manufacturer white paper · 2026 · 1,254 people contributed at least one paired comparison

    Reference: Polar H10 ECG chest strap. Where to look: Figures 1–3.

    Series 12 was compared with six devices during activities including outdoor running, cycling, HIIT, strength and daily living. Figures report the Apple-minus-comparator difference for each outcome.

    Apple used its own internal five-second logger and different export streams for rivals. The paper reports paired differences, which cannot fill an absolute-error column. Oura was excluded from lifting. Designed and published by Apple, which ran two sites. A contract research organization ran three sites.

  • Gillinov et al. · Aerobic exercise

    Peer-reviewed · 2017 · 50 healthy adults

    Reference: ECG and Polar H7 chest strap. Where to look: Abstract and results by exercise.

    Historical device comparisons at rest and during treadmill, bike and elliptical exercise. Agreement varied by exercise modality.

    Older devices and concordance statistics. Useful for the effect of activity, with model-specific results limited to the hardware studied. See the paper for author disclosures.

  • Dial et al. · Overnight heart rate

    Peer-reviewed · 2025 · 13 healthy adults tested across repeated nights

    Reference: Polar H10 single-lead ECG. Where to look: Nightly resting heart rate analyses.

    Oura Gen 3 and Gen 4, Polar Grit X Pro and WHOOP 4.0 were compared with overnight ECG for resting heart rate. HRV was evaluated separately.

    Repeated nights came from a small group. Nightly resting heart rate and live workout heart rate use different sampling windows. Air Force Research Laboratory funding. No competing interests reported.

  • Vora · Free-living and lab recordings

    Public data reanalysis · 2024 · 32 adults in the source study, with device-specific paired subsets

    Reference: Medical-grade ECG. Where to look: Free-living, treadmill and day-one lab activity rows in the 1 Hz files.

    Vora recalculated the size and direction of errors, including the spread between people, from the authors’ aligned ECG and device recordings.

    Scosche Rhythm24 has no free-living data in the release. Laboratory cycling and daily tasks use day one. Counts refer to usable pairs in the released files. The authors reported no conflicts. The analysis uses the public CC BY 4.0 release.

    Original data or supplement

  • Vora · Running and swimming recordings

    Public data reanalysis · 2026 · 10 trained swimmers

    Reference: Polar H10 ECG chest strap. Where to look: Zenodo CSV, split by activity; device models in the source paper.

    The same people wore both watches on land and in the pool. The public file includes only times when all three devices returned a value.

    The chest strap may also be affected underwater. These results describe agreement with the strap during valid pairs. The release cannot tell us how often readings were missing. The original study reported no external funding or conflicts. The CSV is released under CC BY 4.0.

    Original data or supplement

  • Lee, Bae & Ko · Lifting across three visits

    Peer-reviewed · 2026 · 60 healthy men, across three sessions

    Reference: ECG display. Where to look: Tables 2, 3 and 5.

    The authors tested a separate cohort from the 70-person lifting experiment. They recorded displays before the set and 5, 30 and 60 seconds after it, at all three visits.

    The 5-second agreement limits are for individual observations and are marginal across the reference heart rates. The authors found proportional bias for all four devices. No external funding or conflicts reported.

  • Budig et al. · Outdoor exercise and swimming

    Peer-reviewed · 2021 · 36 endurance-trained adults

    Reference: Polar H10 ECG chest strap. Where to look: Table 1.

    The paper reports absolute differences and a percentage measure that divides by the mean reference heart rate.

    Older device models and firmware. The authors call for further testing of the reference strap in water. No external funding or conflicts reported.

  • Navalta et al. · Trail running

    Peer-reviewed · 2020 · 21 healthy adults

    Reference: Polar H7 ECG chest strap. Where to look: Tables 1–3.

    Participants ran uphill and back downhill at a self-selected pace. The Suunto entry uses its accompanying ECG strap. Values are transcribed from the tables.

    Older device models. The authors used different export pipelines for some devices. Device-specific counts and agreement limits are omitted from this extraction. No specific funding or conflicts reported.

    Original data or supplement

  • Nissen et al. · Everyday tasks

    Peer-reviewed · 2022 · 23 healthy adults enrolled, 20 contributed analyzable readings

    Reference: Mind Media NeXus-10 MKI Holter ECG. Where to look: Table 4.

    Participants wore both devices for ten short tasks, from sitting and typing to walking and squats.

    ECG recording issues reduced the available sample for some tasks. Two inconsistent limits in the published table are omitted. No conflicts declared.

  • Kostrna et al. · Stationary cycling

    Peer-reviewed · 2026 · 58 Hispanic adults enrolled, with 33 to 36 usable participants per tested model

    Reference: Polar H10 ECG chest strap. Where to look: Table 1.

    Participants held the cycle handles to limit wrist motion. The table compares the four consumer models with usable data.

    This controlled cycling protocol does not capture the wrist motion of outdoor sports. The usable sample varies by model. NSF PATHS-UP pilot grant. The authors declared no competing interests.

    Original data or supplement

  • Ceugniez et al. · Six field sports

    Peer-reviewed · 2025 · 26 young adults across 55 sessions

    Reference: Polar H10 ECG chest strap. Where to look: Tables 2 and 3.

    The authors aligned and smoothed the time series over ten seconds before computing error.

    The participants and number of sessions differ by sport. Cycling and tennis each had just two participants. No conflicts declared.

  • Miller et al. · Overnight and presleep heart rate

    Peer-reviewed · 2022 · 53 healthy adults

    Reference: Laboratory ECG. Where to look: Table 6 and Figure 2.

    Absolute error is the average size of the difference in summary heart rate. Devices use different windows, including presleep sampling for Polar.

    One laboratory night. These device generations have since been succeeded by newer hardware. Funded by the Australian Institute of Sport. The authors’ lab receives separate support from WHOOP, which had no role in this study.

  • Danielsson et al. · Wheelchair treadmill propulsion

    Peer-reviewed · 2024 · 20 manual wheelchair users and 20 people without a disability

    Reference: Polar H10 ECG chest strap. Where to look: Results, Absolute Agreement.

    The authors combined three incline settings and three stages of increasing speed within each group to estimate mean absolute percentage error.

    The Apple Watch used its wheelchair setting. The Fitbit used treadmill running mode. See the original study’s disclosures.

  • Navalta et al. · Walking, jogging and skipping

    Peer-reviewed · 2023 · 18 adults

    Reference: Polar H10 ECG chest strap. Where to look: Table 3.

    Participants walked, jogged and skipped at self-selected paces in five-minute bouts. Published biases and agreement limits are expressed here as wearable minus reference.

    The published jogging pair count for one model is inconsistent. Pair counts are omitted. See the original study’s disclosures.